8. Mechanical adjustment
[2]
5. Fully tighten the adjustment screws to secure the side guide plate /Rr.
6. For the tray /Lw, reinstall the side guide plate /Rr with two screws.
7. Repeat step 1 to 6 until the misalignment of the punch holes is corrected.
8. Reinstall the adjustment cover.
9. In the service mode, perform [Cover Sheet Feeder Adj.].
See P.22
24
4. Loosen two adjustment screws [1] on
[1]
A07VF3C505DA
Service Manual
Field Service Ver. 2.0 Aug. 2007
the side guide plate /Rr [2] and slide
the side guide plate /Rr twice as long
as the misalignment of the punch
hole position (for example, if the mis-
alignment is 1.5 mm to the rear, slide
3 mm to the rear).
1 index: 2 mm
Y107982-5