Westinghouse WBRC 140W Series Installation Manual page 56

Gas fired residential combi boiler
Table of Contents

Advertisement

Display
Default
1: EH
E0:00
2: cE
OFF
3: In
OFF
4: Fu
GA
Change unit for water volume
Stored water heating function
5: St
ON
6: OH
68 F
Maximum Outdoor Temperature
7: OL
5 F
Minimum Outdoor Temperature
8: FH
00
9: FL
00
10: dr
NO
Initialized burner operation time
11: dI
NO
12: bt
0
13: Ft
1
Set differential temperature to
14: bo
27 F
15: OF
68 F
Warm Weather Shutdown
16: cH
180 F
Maximum supply temperature
17: cL
86 F
Minimum supply temperature
18: dH
140 F
Maximum DHW set temperature
19: cb
100
20: db
100
Internal CH Pump Post Run
21: PP
40
Internal CH Pump Overrun
22: Po
5
Internal CH Pump Overrun
23: PF
0
Detail
Error history up to 10
Delete Error history
Initialized system
"ON", "OFF"
Maximum Fan speed
Minimum Fan speed
Initialized ignition cycle
Boost Function
CH Anti-Frequency time
turn burner "ON"
Heating capacity
DHW capacity
Timer,
T/T Calling for Heat
Timer (On)
Timer (Off)
Check last 10 error codes (E0 - E9)
Select "ON" to delete error code history
Select "ON" to reset to factory setting
(Burner operation time, Ignition cycles, and Supply power time will not be
Select "OFF" to turn off this function
When used with an outdoor sensor, sets the maximum outdoor design
temperature for the system design. Maximum outdoor temperature must be
o
set 9
F above the minimum outdoor temperature.
Range: (Minimum Outdoor Temperature + 9
Sets the minimum outdoor design temperature for the system. Minimum
outdoor temperature must be set 9
o
Range: -4
F to (Maximum Outdoor Temperature - 9
Adjusts Maximum Fan Speed
Adjusts Minimum Fan Speed
Select ON to Initialize burner operation time
Select ON to Initialize ignition cycles
This function boosts CH temperature to the maximum if set point is not
reached within the set period of time.
This function delays burner operation during CH mode
When set, the appliance will operate to heat CH water when water
temperature falls below a differential setting.
Example: If setpoint is 180
on when CH water temperature falls below 153
Warm weather shut down will shut down CH Mode if the programmed
outdoor temperature is exceeded.
Sets the maximum design supply temperature based on the minimum
outdoor design temperature. Maximum supply temperature must be set 9
above the minimum supply temperature.
Range: (Minimum Supply Temperature + 9
Sets the design supply water temperature based on the maximum outdoor
design temperature. Minimum supply temperature must be set 9
maximum supply temperature.
o
Range: 86
F to (Maximum Supply Temperature - 9
Sets Maximum DHW Setpoint temperature
Set Heating combustion rate
NOTE: 199W Models shall be factory set at 70%. The default number will be
70. This percentage can be increased with an additional pump.
Set DHW combustion rate
When appliance CH setpoint is satisfied, but T/T is calling for heat, the
burner will shut OFF and the CH pump will continue to run for this set
This function runs the Internal CH Pump after the Internal CH Pump Post
Run Timer has completed. This will cycle the Internal CH Pump again based
on the default programmed Off and On cycles and repeats until the central
Description
Range: ON or OFF
reset)
Range: ON or OFF
Range: GA or Li
Range: ON or OFF
o
F below the maximum outdoor
temperature.
Range: -30 - +30
Range: -30 -+30
Range: NO or YES
Range: NO or YES
Range: 0 - 120 min
Range: 0 - 20 min
o
o
F and differential is 27
F, the appliance will turn
o
Range: 9 - 27
F
o
Range: 50 - 110
F
o
Range:120 - 140
F
Range: 50 - 100%
Range: 50 - 100%
amount of time
Range: 1 ~ 60 minutes
heating call is satisfied.
Range: 1~60 minutes
56
o
o
F) to 110
F
o
F)
o
F.
o
F
o
o
F) - 180
F
o
F below the
o
F)