Water connection

According to national regulations for drinking water quality, with ef-
fect from 21 March 2021, a non-return valve to prevent backsi-
phoning must be fitted between the stopcock and the water inlet
hose during commissioning on all appliances in Germany. The non-
return valve prevents water from the water inlet hose from flowing
back into the on-site drinking water supply. The non-return valves
are supplied as accessories.
The flow pressure must be a minimum of 100 kPa and must not ex-
ceed 1000 kPa. If the flow pressure is higher than 1000 kPa, a pres-
sure reducing valve must be used.
The machine must be connected to the water supply using the inlet
hoses included in the scope of supply.
 The connection points are subject to water supply pressure.
Turn on the stopcocks slowly and check for leaks. Correct the posi-
tion of the seal and screw thread if appropriate.