Security Network

The device support the security function. When the device included
with a security controller, the device will auto switch to the security
mode. In the security mode, the follow commands need using Security
CC wrapped to communicate, otherwise it will not response.
COMMAND_CLASS_BATTERY
COMMAND_CLASS_NOTIFICATION_V4
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_CONFIGURATION
COMMAND_CLASS_SENSOR_BINARY_V2
COMMAND_CLASS_SENSOR_MULTILEVEL_V5
COMMAND_CLASS_WAKE_UP_V2

Function DIP Switch

There is one function DIP switch in front of the device.
Remove the front cover in the right top of the PCB, and also has mark
"M1" and "M2" for two switch.
Notice: PST02-C don't have DIP switch in hardware.
M1 M2
ON ON Test Mode.
ON OFF Normal Mode.
OFF ON Normal Mode.
Customer Mode. According to the configuration setting
OFF OFF
NO. 5 to set the operation mode.

Operation Mode

There are two modes "Test" and "Normal".
"Test Mode" is for the user test the sensor function when installation.
"Normal Mode" for the normal operation.
Description
When the event triggered, normally the LED won't indicated, unless the
battery is in the low level, the LED will flash once. But in the "Test
Mode" the LED also will light ON one second.
When the event triggered, the device will report the messages to the
nodes in the group 1. The messages also include the battery level, the
temperature and the illumination level. The user can switch the report
by setting the configuration NO. 5 bit4 (illumination) and bit5
(temperature), and the configuration NO. 7 bit6 (battery).
When the event triggered, if the environment luminance is less than
the setting of the value of the configuration NO. 4, the device will emit
the signal to turn ON the lighting equipment, those nodes are in the
group 2. And delay a while to turn OFF the lighting equipment. The
delay time is setting by the configuration NO. 9.
The PIR motion re-detected interval, in the "Test Mode" fixed to 6
seconds. In the "Normal Mode", it according to the setting of the
configuration NO. 8.
Notice: When the tamper key of the back side is released, the device
always in the "Test Mode", no matter the DIP switch setting.