Slim Multisensor PST02-A/B/C
The slim multisensor PST02 has PIR, door/window, temperature and
illumination, 4 sensors function in one, based on Z-Wave
It is the Z-Wave
TM
plus product, it support the security, OTA... Those
newest features of the Z-Wave
communication protocol designed for home automation, specifically to
remotely control applications in residential and light commercial
environments. The technology uses a low-power RF radio embedded or
retrofitted into home electronics devices and systems, such as lighting,
home access control, entertainment systems and household appliances.
This product can be included and operated in any Z-Wave
with other Z-Wave
TM
certified devices from other manufacturers and/or
other applications. All non-battery operated nodes within the network
will act as repeaters regardless of vendor to increase reliability of the
network.
The device adopt the Z-Wave
network system is all made by Z-Wave
network system will have the advantages as below.
TM
technology.
TM
technology. Z-Wave
TM
is a wireless
TM
500 series chip, when your Z-Wave
TM
500 series devices. The
Concurrent multi-channel support reduces external interference.
Better RF range, improve about 10 meters in indoor.
Support 100 Kbps transmit speed, speed up communication.
Function Compare A/B/C
PST02-A
PST02-B
PST02-C
Add to/Remove from Z-Wave
There are two tamper keys in the device, one is in the back side,
another is in the front side. Both of them can add, remove, reset or
association from Z-Wave
In the first time, add the device into the Z-Wave
sure the primary controller is in the add mode. And then power on the
device, just take out the insulation Mylar in the back side of the device.
The device will auto start the NWI (Network Wide Inclusion) mode. And
it should be included in 5 seconds. You will see the LED light ON one
second.
TM
network
Notice: Including a node ID allocated by Z-Wave
"Add" or "Inclusion". Excluding a node ID allocated by Z-Wave
Controller means "Remove" or "Exclusion".
TM
1
PIR
Door/Window Temperature Illumination
V
V
V
V
TM
Network
TM
network.
V
V
V
V
V
V
TM
network. First, make
TM
Controller means
TM

Advertisement

Table of Contents
loading

Summary of Contents for D-Link PST02-A

  • Page 1 Slim Multisensor PST02-A/B/C Concurrent multi-channel support reduces external interference. • Better RF range, improve about 10 meters in indoor. • Support 100 Kbps transmit speed, speed up communication. • Function Compare A/B/C Door/Window Temperature Illumination PST02-A PST02-B PST02-C Add to/Remove from Z-Wave...
  • Page 2: Function Description

    Description Function from Z-Wave Controller. 1. Have Z-Wave Controller entered inclusion mode. Notice 1: Always RESET a Z-Wave device before trying to add it to a 2. Pressing tamper key three times within 1.5 seconds Z-Wave network to enter the inclusion mode. 3.
  • Page 3 device will unsolicited to send the “Sensor Multilevel Report” to the Notification Type: Home Security (0x07) nodes in the group 1. Event: Motion Detection, Unknown Location (0x08) Sensor Type: Temperature (0x01) Sensor Binary Report (V2) Note: To disable this functionality by setting the configuration N0.5 bit5 Sensor Type: Motion (0x0C) to 1.
  • Page 4: Power Up Procedure

    will cause report too frequency, shorter the battery life more. Propose the setting differential value should not small than 10. * PIR Warm Up Caution 2: If the configuration No.4 is setting to 0 or 100, this When the device power on, the PIR need to warm up before the functionality is useless.
  • Page 5: Security Network

    Security Network When the event triggered, normally the LED won't indicated, unless the battery is in the low level, the LED will flash once. But in the “Test The device support the security function. When the device included Mode” the LED also will light ON one second. with a security controller, the device will auto switch to the security mode.
  • Page 7: Battery Installation

    Battery Installation When the device report the low battery message. The user should replace the battery to new one. The battery type is CR123A, 3.0V. The way to open the front cover please follow below steps. 1. Using a tool to press the 1-1 position, to release the cover. 2.
  • Page 8: Installation

    Installation After finish the test and decide to fix, then you can remove tape A, and mounting the sensor by using tape B. The tamper key will pressed and 1. In the first time, add the device into the Z-Wave network.
  • Page 9 Name Description Name Description Def. A B C Def. A B C Valid Valid Setting the BASIC command value to Operation mode. Using bit to control. turn on the light. The 0xFF(-1) means Caution: The value is unsigned byte, the range is from 0x00 ~ 0xFF. turn on the light.
  • Page 10 Name Description Name Description Def. A B C Def. A B C Valid Valid Mult- Multisensor function switch. Using bit Notice: If bit2 is zero, this setting is Sensor to control. useless. Function Caution: The value is unsigned byte, Notice: If the configuration No.9 is Switch the range is from 0x00 ~ 0xFF.
  • Page 11 Name Description Name Description Def. A B C Def. A B C Valid Valid Bit6: Disable to report battery state door/window state.    when the device triggered. (1:Disable, Time The default value is 12. The tick time 0:Enable) can setting by the configuration No.20.
  • Page 12: Z-Wave Supported Command Class

    Name Description Def. A B C Valid Power by CR123A lithium battery. Enable this functionality will cause some issue please see the detail in the Signal (Frequency): “Temperature Report” section. PST02-1: 868.40 MHz, 869.85 MHz(EU), PST02-2: 908.40 MHz, 916.00 MHz(US), The illumination differential to report.
  • Page 13: Fcc Interference Statement

    This device complies with Part 15 of the FCC Rules. Operation is subject This marking indicates that this product should not be to the following two conditions: disposed with other household wastes throughout the EU. (1) This device may not cause harmful interference, and To prevent possible harm to the environment or human (2) This device must accept any interference received, including health from uncontrolled waste disposal, recycle it...