Description
3.3
Measurement field
INFO
The data for your sensor version can be found in the data sheet.
ZP
ZP
Sdc
Measuring range (MR)
Region in which the measurement object must be present for the sensor to deliver reliable
n
measurement results.
Unwanted objects (objects not to be measured) in this region may lead to deviations in the
n
measurement results.
The limits of the measurement range (MR) are defined via the parameters Start of the mea-
n
surement range (Sdc) and End of the measurement range (Sde).
Zero position (ZP)
In the factory settings, the zero point is located on the front of the sensor (ZP = 0 mm). The
n
output consists of the distance between the front of the sensor and the measurement object.
The following values depend on the zero position:
n
▪ Output measured values
▪ Analog value
▪ Switching points
Capable of parameterization via:
n
▪ IO-Link
▪ Teach button
10
Sdc
MR
Sde
Zero position
Start of the measuring range
Operating Manual
MR
Measuring range
Sde
End of the measuring range
OM20/OM30 IO-Link | V6