Description

The submersible pump is designed for home
applications. The unit is equipped with a
3-prong grounding type power cord. Motor
is oil-filled and sealed for cooler running
and designed to operate under water. This
pump is not suitable for aquatic life.

Unpacking

Inspect this unit before it is used.
Occasionally, products are damaged during
shipment. If the pump or components are
damaged, return the unit to the place of
purchase for replacement. Failure to do so
could result in serious injury or death.
Important Safety
Instructions
READ AND FOLLOW ALL INSTRUCTIONS

Safety Guidelines

This manual contains information that is
very important to know and understand.
This information is provided for SAFETY
and to PREVENT EQUIPMENT PROBLEMS.
To help recognize this information,
observe the following symbols:

Specifications

Power supply requirements
BSE50 . . . . . . . . . . . . . . . . . . . . . . . 120V, 60 hz
BSE75, BSE100, and BSE200 . . . . 240V, 60 hz
Motor . . . . . . . . . . . . . . . . . . . . . . . . Single phase, oil filled
Horsepower/Current
BSE50 . . . . . . . . . . . . . . . . . . . . . . . 1/2 HP, 12A @ 115VAC
BSE75 . . . . . . . . . . . . . . . . . . . . . . . 3/4 HP, 7A @ 230VAC
BSE100. . . . . . . . . . . . . . . . . . . . . . 1 HP, 8.5A @ 230VAC
BSE200. . . . . . . . . . . . . . . . . . . . . . 2 HP, 12A @ 230VAC
Liquid temperature range . . . . . . . 40°F to 120°F
Circuit requirements . . . . . . . . . . . . 15 amps (min)
Dimensions. . . . . . . . . . . . . . . . . . . . . . 11 1/2 in. high x 9 3/4 in. base
© 2009 Blue Angel™ Pumps
Please read and save these instructions. Read carefully before attempting to assemble,
install, operate or maintain the product described. Protect yourself and others by
observing all safety information. Failure to comply with instructions could result in
personal injury and/or property damage! Retain instructions for future reference.
Sewer Ejector
Pump
hazardous situation which, if not avoided,
WILL result in death or serious injury.
hazardous situation which, if not avoided,
COULD result in death or serious injury.
hazardous situation which, if not avoided,
MAY result in minor or moderate injury.
information, that if not followed, MAY
cause damage to equipment.
General Safety
Information
CALIFORNIA PROPOSITION 65
contain chemicals known to the State
of California to cause cancer and birth
defects or other reproductive harm.
Wash hands after handling.
REMINDER: Keep your dated proof of purchase for warranty purposes!
Attach it to this manual or file it for safekeeping.
For parts, product & service information
visit www.blueangelpumps.com
Danger indicates an

GENERAL SAFETY INFORMATION

imminently
pump fl ammable or explosive
Warning indicates a
fl uids such as gasoline, fuel
potentially
oil, kerosene, etc. Do not
use in a fl ammable and/or explosive
atmosphere. Personal injury and/or
Caution indicates a
property damage could result.
potentially
to handle salt water, brine, laundry
Notice indicates
discharge or any other application
important
which may contain caustic chemicals
and/or foreign materials. Pump damage
could occur if used in these applications
and will void warranty.
qualifi ed electrician.
This product or
If the basement has water
its power cord may
or moisture on the fl oor, do
not walk on wet area until all
power is turned off. If the shut-off box
is in the basement, call an electrician.
Remove pump and either repair or replace.
Failure to follow this warning could result
in fatal electrical shock.

Construction

Motor housing . . . . . . . . . . . Cast Iron
Volute . . . . . . . . . . . . . . . . . . Cast Iron
Impeller . . . . . . . . . . . . . . . . . Cast Iron
Shaft . . . . . . . . . . . . . . . . . . . Low carbon steel
Seals . . . . . . . . . . . . . . . . . . . . Buna N
Discharge . . . . . . . . . . . . . . . 3 in. NPT
BSE50, BSE75,
BSE100 and BSE200
Do not
use to
This pump is
not designed
All wiring must be
performed by a
2 in. NPT (Adapter included)
332202-002 2/09

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BSE50 and is the answer not in the manual?

Questions and answers

Summary of Contents for Blue Angel Pumps BSE50

  • Page 1 Motor housing ... Cast Iron BSE50 ..... . . 1/2 HP, 12A @ 115VAC Volute .
  • Page 2 Operating Instructions and Parts Manual Installation General Information Functionally, the liquid in the basin rises and trips the first float, but the pumps do Always Sewage Pump Systems: not turn ON. As the liquid level rises, it disconnect trips the second float, activating one of the Simplex System the power source before pumps.
  • Page 3 Operating Instructions and Parts Manual 6. Drill a 1/8 in. hole in the discharge power cords will be brought through Installation (Continued) pipe 1 to 2 inches above the flange. the appropriate openings in the This will prevent air locking and loss basin cover.
  • Page 4 Operating Instructions and Parts Manual Operation Maintenance 2. Disassembly of the motor prior to (Continued) expiration of warranty will void the warranty. If repairs are required, see 2. With the cover uninstalled, add Always disconnect troubleshooting chart. the electrical water to the basin and observe the supply before attempting to install, float control switch operation.
  • Page 5 Operating Instructions and Parts Manual Troubleshooting Chart Symptom Possible Cause(s) Corrective Action Pump will not start or run 1. Blown fuse, tripped breaker 1. If blown, replace with proper sized fuse or reset breaker 2. Low line voltage 2. If voltage is under 108 volts, check wiring size 3.
  • Page 6 For Replacement Parts or Technical Assistance, Call 1-888-636-6628 Please provide following information: Address any correspondence to: - Model number Blue Angel Pumps - Serial number (if any) 101 Production Drive - Part description and number as shown in parts list Harrison, OH 45030 U.S.A.
  • Page 7 Operating Instructions and Parts Manual Notes www.blueangelpumps.com...
  • Page 8 Operating Instructions and Parts Manual Limited Warranty For two (2) years from the date of purchase, Blue Angel will repair or replace, at its option, for the original purchaser any part or parts of its Sump Pumps or Water Pumps (“Product”) found upon examination by Blue Angel to be defective in materials or workmanship.

This manual is also suitable for:

Bse75Bse100Bse200

Table of Contents