e. Partially frontseat (turn clockwise) the suction service
valve and slowly add charge until the refrigerant
appears at the proper level .
6.8 COMPRESSOR
WARNING
Make sure power to the unit is OFF and
power plug disconnected before replacing
the compressor.
NOTES
1
The compressor should not operate in a
vacuum greater than 500 mm/hg (20
inches/hg).
2
The service replacement compressor is
sold without shutoff valves (but with valve
pads), and without terminal box and cover.
Customer should retain
terminal box, cover, and high pressure
switch for use on replacement compressor.
3
Check oil level in service replacement
compressor. (Refer to paragraph 6.8.6.)
4
A compressor terminal wiring kit must be
ordered as a separate item when ordering
replacement
compressor.
installation instructions are included with
kit.
5
Refer to Table 6-7 and Table 6-8 for
applicable compressor wear limits and
torque values.
6
Refer to Figure 6-37 for charts on
compressor pressure, temperature and
motor current curves.
6.8.1 Removal and Replacement of Compressor
a. Remove the protective guard from lower section of
the unit.
b. Pump down low side (refer to paragraph 6.4) or front-
seat compressor service valves and remove refriger-
ant from compressor using a refrigerant recovery
system.
c. Locate the compressor junction box. Tag and discon-
nect wiring from compressor terminals and remove
compressor junction box.
d. Loosen service valve mounting bolts, break seal and
then remove bolts.
e. Remove compressor plate mounting bolts.
f. Remove compressor and mounting plate. Refer to
paragraph 2.2 for weight of compressor.
g. Remove high pressure switch (HPS) from compres-
sor and check operation of switch (refer to paragraph
6.9.2).
16
15
14
13
12
11
1. Discharge Valve
2. High Side Pressure
the original
3. Low Side Pressure
4. Suction Valve Flange
5. Motor End Cover
6. Serial/Model No. Plate
7. Crankcase Heater
Appropriate
h. Remove compressor mounting bolts from mounting
i. Install replacement compressor terminal wiring kit,
j. Install high pressure switch on compressor.
k. Install compressor and mounting plate in unit.
l. Connect junction box(es) to compressor and connect
m. Install new gaskets on service valves.
n. Install mounting bolts in service valves and torque to
o. Attach two hoses (with hand valves near vacuum
p. Fully backseat (open) both suction and discharge
q. Remove vacuum pump lines.
r. Start unit and check refrigerant charge. (Refer to
s. Check moisture-liquid indicator for wetness. Change
t. Check compressor oil level per paragraph 6.8.6. Add
6-5
1
2
10
8
9
7
Flange
Connection
Connection
Figure 6-6 Compressor
plate and install mounting plate on replacement com-
pressor.
following instructions included with kit.
all wiring per wiring diagram. Install junction box
cover(s).
2.77 to 4.15 mkg (20-30 ft/lb).
pump) to the suction and discharge service valves.
Dehydrate and evacuate compressor to 500 microns
(75.9 cm Hg vacuum = 29.90 inches Hg vacuum).
Turn off valves on both hoses to pump.
service valves.
paragraph 6.7.)
filter-drier if necessary. (Refer to paragraph 6.13.)
oil if necessary.
3
4
5
6
8. Bottom Plate
9. Sight Glass
10. Oil Drain Plug
11. Oil Charging Valve
12. Bearing Head
13. Oil Pump
14. Oil Fill Plug
15. Cylinder Head
16. Valve Plate
T-285