Troubleshooting; Cleaning And Maintenance - Dometic DM20 D CL Installation And Operating Manual

Table of Contents

Advertisement

Available languages

Available languages

Troubleshooting

1. Press the setting button (fig. 3 4, page 4) and keep it pressed for 5 s, until the
lamp (fig. 3 1, page 4) starts to blink.
2. Press immediately the setting button (fig. 3 4, page 4) again.
✔ The lamp (fig. 3 1, page 4) indicates the setting temperature:
– 5 °C (41 °F): the lamp flashes five times in three intervals
– 12 °C (54 °F): the lamp flashes once in three intervals
– 7 °C ( 45 °F): the lamp flashes three times in three intervals
I
NOTE
The minibar sets the cooling temperature automatically to 7 °C (47 °F),
when it is connected to a power source.
8
Troubleshooting
Fault
Device does not
function, Status LED
does not glow.
The device does not
cool (plug is inserted,
Status LED glows).
The Error LED flashes
once per second.
Device does not cool
sufficiently, Status LED
glows, Error LED does
not glow.
9

Cleaning and maintenance

A
NOTICE! Damage hazard
• Never clean the cooling device under running water or in dish water.
• Do not use abrasive cleaning agents or hard objects during cleaning
as these can damage the cooling device.
20
Possible cause
No voltage present in
the AC voltage socket.
The mains adapter is
defective.
The cooling element is
defective.
Temperature sensor is
defective.
The cooling element is
defective.
Poor ventilation
DM20 D CL, DM20 F CL
Suggested remedy
Try using another plug socket.
Contact service agent.
Contact service agent.
Contact service agent.
Contact service agent.
Check the ventilation.
Clean the filter underneath the device.
EN

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dm20 f cl

Table of Contents