Dometic Rm2351 Installation Manual

Dometic Rm2351 Installation Manual

Refrigerator for lp-gas & electric operation

Advertisement

Rm2351
Rm2554
Rm2354
Dm2652
Rm2451
Dm2662
Rm2454
Dm2663
Rm2551
Dm2852
FOR YOUR SAFETY
If you smell gas:
1. Open windows.
2. Don't touch electrical switches.
3. Extinguish any open flame.
4. Immediately call your gas supplier.
FOR YOUR SAFETY
Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
!
WARNING
Improper installation, adjustment, altera-
tion, service or maintenance can cause
injury or property damage. Refer to this
manual. For assistance or additional infor-
mation consult a qualified installer, serv-
ice agency or the gas supplier.
USA
Service Office
Dometic Corporation
2320 Industrial Pkwy.
Elkhart, IN 46516
Phone: 574-294-2511
825125807
(French 825125857)
©2006-2007 Dometic Corporation
LaGrange, IN 46761
®
Dm2862
Dm3862
nDm1062
nDR1292
Corporate Office
2320 Industrial Parkway Elkhart, IN 46515
For Service Center Assistance
Call: 800-544-4881
installation
manual
RefRigeRatoR foR LP-gas
& eLectRic oPeRation
POUR vOTRE SéCURITé
Si vous sentez une odeur de gaz:
1. Ouvrez les fenêtres.
2. Ne touchez à aucun interrupteur.
3. Éteignez toute flamme nue.
4. Avertissez immédiatement votre
fournisseur de gaz.
POUR vOTRE SéCURITé
Ne pas entreposer ni utiliser de l'essence
ni d'autres vapeurs ou liquides inflamma-
bles à proximité de cet appareil ou de tout
autre appareil.
AVERTISSEMENT
!
Une installation, un réglage, une modifi-
cation, une réparation ou un entretien non
conforme aux normes peut entraîner des
blessures ou des dommages matériels.
Lisez attentivement le mode d'emploi
fourni avec l'appareil. Pour obtenir de
l'aide ou des renseignements supplémen-
taires, consultez un installateur ou un
service d'entretien qualifié ou le fournis-
seur de gaz.
®
CANADA
Dometic Corporation
48 Zatonski, Unit 3
Brantford, ON N3T 5L8
CANADA
Phone: 519-720-9578
MO-M 0742

Advertisement

Table of Contents
loading

Summary of Contents for Dometic Rm2351

  • Page 1 2320 Industrial Parkway Elkhart, IN 46515 Dometic Corporation Dometic Corporation 48 Zatonski, Unit 3 2320 Industrial Pkwy. Brantford, ON N3T 5L8 Elkhart, IN 46516 For Service Center Assistance CANADA Phone: 574-294-2511 Call: 800-544-4881 Phone: 519-720-9578 825125807 MO-M 0742 (French 825125857) ©2006-2007 Dometic Corporation LaGrange, IN 46761...
  • Page 2: Table Of Contents

    intRoDuction This manual describes the installation procedure of RM351, RM354, RM451, RM454, RM551, RM554, DM65, DM65 (with optional fan), DM66, DM663, DM85, DM85 (with optional fan), DM86, DM86 (with optional fan), DM386, NDM106 and NDR19. The installation is to be performed by qualified personnel only and must conform to all relevant local authorities. Please read this manual thoroughly before installing the refrigerator.
  • Page 3: Certification And Code Requirements

    ceRtification anD coDe RequiRements This appliance is certified under the latest edition of ANSI Z21.19•CSA 1.4 Refrigerators using gas fuel. The installation must conform with local codes, or in absence of local codes, the following standards as applicable. In the U.S. the installation must conform with: In CANADA, the installation must conform with: •...
  • Page 4: Ventilation Heights

    (K) the refrigerator. Bottom (L) Minimum ventilation heights Rear (M 0 / 1 (RM2351 & RM2354) Roof vent and Upper and lower The distance between the rearmost part of the refrigerator and the wall lower side vent side vent behind it.
  • Page 5: Overall And Recess Dimensions

    ventilation RequiRements oveRall anD Recess Dimensions Dimensions Overall Recess Model Height a Width B Depth C Height H Width W Depth D 30-5/3 21-7/8 -/3 9-3/4 0-1/ 1-3/8 inches RM351 RM354 37-3/8 24-7/8 4-11/16 39-9/16 3-11/16 inches RM451 RM454 43-1/ 24-7/8 4-11/16 4-5/8...
  • Page 6: Installation Instructions

    Make sure the floor is solid and level. enclosure with screws (not included). • The refrigerator must be level and installed in a substantial Rm2351 & Rm2354 enclosure. Install the five screws in the following order: • Do not install the appliance directly on carpeting. Carpet- ing must be removed or protected by a metal or wood panel Four screws installed through the front frame.
  • Page 7 installation instRuctions One screw installed in the rear base. Rm2451, Rm2454, Rm2551, Rm2554, Dm2652, Dm2662, Dm2663, Dm2852, Dm2862, Dm3862 & nDm1062 Install the screws in the following order: Two screws installed through the front base. (Installation of the lower front strip.) The refrigerator is provided with a lower front strip (shipped as a loose part).
  • Page 8: Connections

    Allow the burner to operate for a minimum of five minutes. connections Rm2351, Rm2451, Rm2551, Dm2652 & Dm2852 Gas connection To test the gas safety shut off, follow these steps: Hook up to the gas supply line is accomplished at the manual start the refrigerator without connecting to gas valve, which is furnished with a 3/8”...
  • Page 9: Electrical Connection

    APPENDIx A - REARVIEW EqUIPMENT • RM2351 & RM2354 Correct polarity must be observed when connecting to the DC To the left of the refrigerator and 4-6” above the refrigerator supply. Do not use the chassis or vehicle frame as one of the mounting floor conductors.
  • Page 10: Mounting Instructions

    mounting instRuctions ReveRsing the DooR swing With screws To mount the panel, follow these steps: For all models, except NDR1292, the refrigerators are equipped with hinges that makes it possible to change the direction the Open the door 90 degrees. door opens by moving the hinges to the opposite side.
  • Page 11: Refrigerator Removal

    mounting instRuctions Snap in To mount the panel, follow these steps: Open the door 90 degrees. On new refrigerators, the decoration strip are taped inside the door; if installed on the door, remove the door decoration strip (2) by gently pushing the four tabs away with a flat blade screwdriver (1).
  • Page 12: Appendix A - Rearview Equipment

    - ReaRview equipment Rm2351 Heater Flue baffle Drain water hose Power module cover Protection cover Screw for protection cover Burner jet 12 V DC Manual gas shutoff valve Terminal block Inlet fitting Flexible cord Rm2354 Heaters Relay Flue baffle...
  • Page 13 appenDix a - ReaRview equipment Rm2451, Rm2454, Rm2551 & Rm2554 Heater Relay, 3-way only Flue baffle Power module cover Protection cover 12V DC Screw for protection cover Burner jet 12 volt Terminal block Manual gas shutoff valve Inlet fitting Flexible cord Drain water hose Dm2652, Dm2662, Dm2663, Dm2852, Dm2862, Dm3862 &...
  • Page 14 appenDix a - ReaRview equipment nDR1292 Heaters Power module cover Thermofuse Flue baffle Protection cover Burner jet Drain water hose Manual gas 12 volt shutoff valve Flexible cord Terminal block Inlet fitting - 14 -...
  • Page 15: Appendix B - Wiring Diagrams

    B - wiRing DiagRams Rm2351, Rm2451 & Rm2551 Rm2354, Rm2454 & Rm2554 - 15 -...
  • Page 16 appenDix B - wiRing DiagRams Dm2652, Dm2662, Dm2852 & Dm2862 Dm2652, Dm2852 & Dm2862 (moDels equippeD with optional fan) 3 8 5 1 3 9 1 G R E E N P 1 − 1 P 3 − 4 O R A N G E P 1 −...
  • Page 17 appenDix B - wiRing DiagRams Dm2663 Dm3862 - 17 -...
  • Page 18 appenDix B - wiRing DiagRams nDm1062 (ss)* 3 8 5 1 3 9 2 G R E E N P 1 − 1 P 3 − 4 O R A N G E P 1 − 4 P 3 − 3 B L U E P 1 −...
  • Page 19 appenDix B - wiRing DiagRams nDR1292 (ss)* 3 8 5 1 3 3 0 G R E E N P 1 − 1 P 3 − 4 O R A N G E P 1 − 4 P 3 − 3 B L U E P 1 −...
  • Page 20 TO The INSTALLeR PLEASE AFFIx THESE INSTRUCTIONS TO THE REFRIGERATOR — TO The CONSUMeR PLEASE RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE...

Table of Contents