Electrical Connections (Stacked Ovens) - Vulcan-Hart VC5 Series Installation & Operation Manual

Electric convection ovens
Hide thumbs Also See for VC5 Series:
Table of Contents

Advertisement

ELECTRICAL CONNECTIONS (Stacked Ovens)

Make sure that the electrical power supply agrees with the
wiring diagram on the oven and Electrical Data, page 5.
1. Wires to connect both ovens are provided with each oven (X, Y, Z). Carefully route these from
top oven through the bushing (supplied with the stacking kit) through the electrical access
knockout holes common to both ovens. Wires are at least 12 AWG with a 150 degree C rating.
2. Connect wires X, Y and Z from the upper oven to the lower oven per the wiring diagram. Attach the
power supply conduit to the bottom of the lower oven. Connect the power supply leads to the
line side of the terminal block on the bottom oven.
3. Finally, inspect and check all wiring and terminal connections for tightness or pinch points (cover
on oven frame).
4. Refer to reference drawing 426986 supplied with the stacking kit for electrical connection
instructions.
5. Refer to instructions supplied with the stacking kit for marking the combined electrical load
information to the electrical data plate of the bottom oven.
– 7 –
on the oven data plate, the

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vc5edMl-137047