13.3 Optional CD Ozone Water Maintenance System

If you have elected to have your spa equipped with the optional Jacuzzi CD
ozone water purification system you will find that your water stays fresh and
clear with significantly less chemical sanitizer usage. You will also probably be
able to go longer between complete spa drainings.

14.0 Error Conditions/Error Messages

Your spa has a self-diagnostic control system. The system will automatically
display the following if a problem is detected.

14.1 Summer Logic (Spas With Circulation Pump Option)

When the actual spa water temperature reaches up to 2°F (1°C)
above the set temperature, the spa goes into "summer logic."
The 24-hour circulation pump will turn off automatically to
avoid adding additional heat to the water, eventually creating
an overheat condition. This setting is not user-programmable.
Note: The summer logic does not take effect until the spa water temperature
reaches 95°F (35°C). This condition is more likely in excessively hot weather.
Remember, the spa' s ability to cool is directly affected by the ambient temperature.
An excessively hot ambient temperature may prevent the spa from cooling down
because it' s fully insulated construction is designed to retain heat and to minimize
operating costs.

14.2 Panel Displays COL

Cool Condition - Temperature has dropped 20°F (11°C) below
the current set temperature. Jets pump 1, (or optional circula-
tion pump) and the heater have been activated to bring the
temperature to within 15°F (8°C) of the set temperature. No corrective action is
required! Note: this condition is common during first time fillups or during refills
since tap water is often very cold.

14.3 Panel Displays ICE

Freeze Protection - A potential freeze condition has been
detected. No action is required. Jets pump (or optional circula-
tion pump) and heater will operate to circulate and warm water
through the plumbing until spa is out of DANGER. See "Winterizing" (page 31).

14.4 Panel Displays SN1

Open sensor (heater is disabled) or shorted sensor (spa is
deactivated). The high-limit temperature sensor is not function-
ing. Contact your authorized Jacuzzi dealer or qualified service
technician.