Drive concepts
Drive concepts
SIMATIC MICRO-DRIVE
SIMATIC MICRO-DRIVE
Voltage
The drive is a built-in part without an isolating switch.
→ Only connect the drive to Siemens drive controllers PDC (=Profi Drive Control) or F-TM ServoDrive.
CAUTION
→ When working on the drive, it is imperative that the system/machine is brought to a standstill and secured
against switching on again.
Electrostatic charging
Risk of damaging electronic components
→ Use ESD protective equipment during assembly and disassembly.
NOTICE
Prerequisites for connection and start-up:
• Before connecting the drive, make sure that the power supply matches the product voltage.
• Check whether the information on the nameplate or in the detailed specification matches the connection data
of the Siemens drive controller.
NOTICE
• Only use cables designed for the Siemens product partner range according to the nameplate and the
corresponding ambient conditions. Ensure the mechanical protection of the electrical hookup.
• Ensure that the power supply lines are not mixed up.
5.1 Assembly conditions
The drive can be installed in any desired location directly on or in the machine using four screws.

5.2 Mechanical installation

1. Mechanically install the drive using at least 4 screws (for required screws and fastening points, see "4.6 Dimensional draw-
ings" on page 17) at the fastening points in or on the machine.
2. Electrically connect the drive in the machine/switch cabinet using plugs, for interfaces, see chapter "5.3 Electrical installation"
on page 22.
3. Establish the power supply.