Flange mounted clutch with electronic slip detector (21 pages)
Summary of Contents for Nexen AIR CHAMP Burke E. Porter 5H50P
Page 1
Burke E. Porter 5H50P Multiposition Tooth Clutch FORM NO. L-20222-G-0501...
Page 2
In accordance with Nexen’s established policy of constant product improvement, the specifications contained in this manual are subject to change without notice. Technical data listed in this manual are based on the latest information available at the time of printing and are also subject to change without notice.
Accordingly, anyone who uses a procedure that is not recommended by Nexen must first satisfy themselves that neither their safety or the safety of the product will be jeopardized by the service method selected.
The 5H50P Tooth Clutch has a drive flange with two bearings, a pilot diameter, and tapped holes for mounting Nexen's Flexible Coupling. 5H50P NOTE: Nexen recommends using a red anaerobic thread locking compound on Pilot Mounting Bolts. The 5H50P mounts on a full shaft using a full length Key.
NOTE: Pneumatically actuated devices require clean, pressure regulated, and lubricated air for maximum performance and long life. The most effective and economical way to lubricate Nexen 5H50P is with an Air Line Lubricator, which injects oil into the pressurized air, forcing an oil mist into the air chamber.
LUBRICATOR DRIP RATE SETTINGS NOTE: These settings are for Nexen supplied lubricators. If you are not using a Nexen lubricator, calibration must replicate the following procedure. 5. Connect the air line to the unit. 1. Close and disconnect the air line from the unit.
PARTS REPLACEMENT DISASSEMBLY Drive Special attention should be exercised when Flange working with retaining rings. Always wear safety goggles when working with spring or tension loaded fasteners or devices. 1. Remove Retaining Ring (Item 11) (See Figure 4). (Item 1) NOTE: If a press is not available, use a bearing puller to remove Drive Flange from the Hub.
Page 9
DRIVE FLANGE BALL BEARINGS (Item 9) Special attention should be exercised when working with retaining rings. Always wear safety goggles when working with spring or tension loaded fasteners or devices. 1. Remove Retaining Ring (Item 10) (See Figure 7). 2. Push the Ball Bearings (Item 9) out of Drive Flange (Item 15) (See Figure 7).
Page 10
PISTON BALL BEARING (Item 9) Special attention should be exercised when working with retaining rings. Always wear safety goggles when working with spring or tension loaded fasteners or devices. 1. Remove Retaining Ring (Item 11) (See Figure 9). 2. Press Hub (Item 1) out of Piston (Item 3) and Ball Bearing (Item 9) (See Figure 9).
Hub, Piston, Cylinder Assembly FIGURE 12 REPLACEMENT PARTS The item or balloon number for all Nexen products is used When ordering replacement parts, specify model for part identification on all product parts lists, product designation, item number, part description, and quantity.
Exclusive Remedy The exclusive remedy of the Buyer for any breach of the warranties set out above will be, at the sole discretion of Nexen, a repair or replacement with new, serviceably used or reconditioned Product, or issuance of credit in the amount of the purchase price paid to Nexen by the Buyer for the Products.