Problem
The door can be pushed
or pulled open by hand
although it should be
locked.
No status feedback re-
ceived from the lock.
The bolt jumps back out
of the lock immediately
after opening the door.

Problems, causes, solutions

All manuals and user guides at all-guides.com
Problems, causes, solutions
Updated information
Cause
The bolt is not extended when the door is closed.
Flip latch cannot freely engage in the strike plate.
The bolt is not extended when the door is closed.
Locking cylinder jammed.
The bolt is not extended when the door is closed.
The trip latch is not actuated.
Incorrect connection of the individual contacts or
short circuit due to incorrect polarisation.
The trip latch is not retained in position for perma-
nent door release.
The door handle was not pressed down completely.
Door handle cannot be pushed down far enough.
Rebate gap is set too wide.
The trip latch jams in an actuated position.
Updated information, such as reports relating to additionally executed fire tests can be found at:
www.assaabloy.ch
Solution
Adjust the door and the position of the strike plate
so that the flip latch engages freely in the strike
plate and door frame and can position itself.
Check and replace the locking cylinder if necessary.
Check switchover operation using a key.
Check and, if necessary, correct the rebate gap.
Check the electrical connections and, if necessary,
measure the continuity of the connection cable.
Press the door handle right down to the end stop.
Check and, if necessary, correct the rebate gap.
Check that the lock has been installed without dis-
tortion and, if necessary, correct the installation.