5.11
Closing the burner
Once the combustion head adjustment is completed:
reassemble the burner on the guides 3) at about 100 mm
from the pipe coupling 4) - burner in the position shown in
Fig. 16;
insert the electrode cables and then slide the burner up to
the pipe coupling;
connect the tie-rod 14) to the sector 15);
connect the socket of the maximum gas pressure switch;
20121303
Installation
replace screws 2) and lifting rings on the two slide bars 3);
connect the light oil pipes by screwing the two fittings 16);
fix the burner to the pipe coupling with the screws 4).
WARNING
4
3
2
26
GB
When fitting the burner on the two slide bars, it is
advisable to gently draw out the high voltage ca-
ble and the flame detection probe cable until they
are slightly stretched.
16
15
14
20107998
Fig. 27