Voltage, V
380 Y
400 D
400 Y
415 D
440 D
500 D
500 Y
525 D
550 D
660 Y
690 Y
1000 Y
BS/KS, 60 Hz
Motor type:
• 2 pole
• 3,480 rpm
• 4.4 kW (5.9 hp)
Voltage, V
200 D
208 D
220 D
220 Y//
230 D
230 Y//
240 D
240 Y//
380 D
380 Y//
400 D
400 Y//
440 D
440 DSER
440 Y
440 YSER
460 D
460 DSER
460 Y
460 YSER
480 D
480 Y
480 YSER
575 D
575 Y
Flygt 2830.180 Installation, Operation, and Maintenance Manual
Rated current, A
Starting current, A
7.3
46
7.3
49
7.3
49
6.9
43
6.9
46
6
40
5.4
40
5.2
32
5.3
34
4.3
26
4.2
28
2.9
19
Rated current, A
Starting current, A
17
127
17
133
15
104
15
103
15
109
15
110
15
115
15
114
8.7
63
9.3
72
8.7
67
9.8
77
7.3
49
8
63
7.2
49
7.4
52
7.1
53
8.4
66
6.9
52
7.3
54
7.1
54
6.7
54
7.5
57
5.8
43
5.5
43
Technical Reference
Power factor, cos φ
0.92
0.88
0.88
0.9
0.85
0.86
0.93
0.94
0.88
0.92
0.88
0.88
Power factor, cos φ
0.88
0.84
0.92
0.91
0.89
0.88
0.84
0.83
0.9
0.85
0.85
0.77
0.93
0.84
0.95
0.91
0.91
0.78
0.94
0.88
0.87
0.92
0.83
0.89
0.94