Ferroli Sigma 30 FF 41-267-07 Installation And Servicing Instruction page 17

Wall mounted cast iron, gas fired boiler for central heating fan assisted, room sealed, electronic flame ignition and control
Table of Contents

Advertisement

2.07.03 Terminal Position
Pos. Minimum spacing ............................................................. mm
A
Directly below an openable window, air vent,
or any other ventilation opening ........................................... 300
B
Below gutters, soil pipes or drainpipes .................................. 75
C
Below Eaves ........................................................................... 100
D
Below a Balcony ..................................................................... 100
E
From vertical drainpipes or soilpipes ...................................... 75
F
From internal or external corners ......................................... 100
G
Above adjacent ground or balcony level .............................. 100
H
From a surface facing the terminal ....................................... 600
I
Facing another terminal ..................................................... 1,200
J
From opening (door/window) in carport into dwelling ..... 1,200
K
Vertically from a terminal on the same wall .......................... 300
L
Horizontally from a terminal on the same wall ..................... 300
N
Below carport ........................................................................ 600
A Quinnel Barrat and Quinnel guard (part. No. C2) should be screwed to the wall centrally over the terminal, when the
distance is less than 2 m from the outside floor.
2.08 Electrical connection
The boiler must be connected to a single phase 230V 50Hz electricity supply with a 3 A max. fuse and a bipolar switch with
contact opening of at least 3 mm fitted between the boiler and the electricity supply. The boiler must always be connected
to an efficient earth installation. In the electrical box, there is a 3 pole terminal block for connecting the boiler to the mains
(230V 50Hz) and a 3 pole block for connecting a circulating pump (not supplied). See Wiring diagram (fig. 41a) for the
connection of external control.
When the boiler is connected to an electricity main, it is essential TO ENSURE CORRECT POLARITY (LIVE: brown cable,
NEUTRAL: blue cable, EARTH: yellow-green cable).
All wiring must conform to current I.E.E. regulations.
Note: If the power supply cable has to be replaced, use "0.75mm (24/0.20) cable only to BS6500 with a maximum external
diameter of 8 mm.
X4
101
X3
G C P
JP
Key
63. CH temperature setting
86. Reset switch
101. Main P.C.B.
121. Boiler shut-down warning (Led)
X3-X4-X5-X8. Connectors
JP. Link
1
4
1
X8
121
63
Sigma
F
L
X5
5
Temp.
86
sensor
NTC 34
Fig. 39
F
F
E
Fig. 38
Temp.
kOhm
25°C
1000 kOhm
60°C
185 kOhm
80°C
80 kOhm
17