AXIS Q6055 PTZ Dome Network Camera
Specifications
NOTICE
NO
NO
TICE
TICE

Multicable connectors

When connecting external equipment to the Axis product, an Axis multicable is required in order to maintain the product's IP rating.
The Axis multicable can be purchased from your Axis reseller. To locate the multi-connector, see Product overview on page 2 .
The multicable provides the following connectors:
Power connector - 3-pin terminal block used for power input. Use a Safety Extra Low Voltage (SELV) compliant limited power source
(LPS) with either a rated output power limited to ≤100 W or a rated output current limited to ≤5 A.
Audio in (pink) - 3.5 mm input for a mono microphone, or a line-in mono signal (left channel is used from a stereo signal).
Audio out (green) - 3.5 mm output for audio (line level) that can be connected to a public address (PA) system or an active speaker
with a built-in amplifier. A stereo connector must be used for the audio out.
I/O terminal connector - Use with external devices in combination with, for example, tampering alarms, motion detection, event
triggering, and alarm notifications. In addition to the 0 V DC reference point and power (DC output), the I/O connector provides the
interface to:
Digital output — For connecting external devices such as relays and LEDs. Connected devices can be activated by
the VAPIX® Application Programming Interface or in the product's webpage.
Digital input — For connecting external devices that can toggle between an open and closed circuit, for example
PIR detectors, door/window contacts, and glass break detectors.
I/O connector
Function
0 V DC (-)
DC output
Configurable (Input
or Output)
DC power input
Pin
Notes
1
2
Can be used to power auxiliary equipment.
Note: This pin can only be used as power out.
3–6
Digital input – Connect to pin 1 to activate, or leave
floating (unconnected) to deactivate.
Digital output – Connected to pin 1 when activated,
floating (unconnected) when deactivated. If used with
an inductive load, e.g. a relay, a diode must be connected
in parallel with the load, for protection against voltage
transients.
AC power input
17
Specifications
3.3 V DC
Max load = 250 mA
0 to max 40 V DC
0 to max 40 V DC, open
drain, 100 mA