5.1.10c 
5.1.10d 
5.1.10e 
5.1.10f 
Canister motor test:
• remove the canister(s)
• press
,
pulse
result: the canister motor runs briefly at 20%
speed
• press
,
cycle
result: the canister motor runs at 20% speed
for 10 seconds
• press or to select another canister
Mixer motor test:
• press
to select a mixer in the next
test
screen
► The number of mixer motors may vary per
configuration, see §7.3 on p.128.
• press or to select another component
Mixer motor test:
• press
,
pulse
result: the mixer motor runs briefly at full
speed
• press
,
cycle
result: the mixer motor runs at full speed for
10 seconds
• press or to select another mixer
Low pressure pump test:
• press
,
pulse
result: the pump motor runs briefly
• press
,
cycle
result: the pump motor runs for 10 seconds
► The water will not reach the mixing cup.
• press or to select another component