Disable Walk Test
To end every walk tests—except the "AML Smoke Test"—this option must
be selected. Once you have completed your test, enter [
Code]. Use the arrow keys to scroll to this option and press [
partition will return to its normal disarmed state. The walk test mode will
also be automatically disabled if the partition is armed.
Press the [#] key to exit the walk test menu.

5.2 Performing a System Test

This option will test the system. This bell/siren will activate for two
seconds and system will send a test code transmission to the monitoring
station. To start the System test, perform the following:
1. Press [
Master" or "Supervisor" option enabled.
2. Press [1] to enter the Functions menu.
3. Press [0] to enter "System Test." When the test is finished, press [#]
to exit.

5.3 Performing a Lamp Test (PC4216)

This test will activate all outputs on the PC4216 output module for two
seconds. To execute this test, perform the following:
1. Press [
Master" or "Supervisor" option enabled.
2. Press [1] to enter the Functions menu.
3. Press [3] to enter "Lamp Test 4216." All outputs connected to the
PC4216 output module will activate for two seconds. When the test
is finished, press [#] to exit.

5.4 System Maintenance

With normal use, the system requires minimum maintenance. The
following points should be observed.
1. Do not wash the keypad with a wet cloth as water will damage the
keypad circuits. Light dusting with a slightly moistened cloth should
remove normal accumulations of dust.
2. The battery/bell test is designed to determine battery condition. We
recommend, however, that the stand-by batteries be replaced every
three years. Contact your installation company for service.
3. Do not attempt to replace the small round lithium battery on the
control panel circuit board. It is not replaceable. If you suspect there
is a problem with your equipment, call your installation company
for service.
4. For other system devices such as smoke detectors, passive infrared,
ultrasonic or microwave motion detectors and glassbreak detectors,
consult the respective manufacturer's literature for testing and
maintenance instructions.
30
] [6], then enter a valid [access code] which has the "System
] [6], then enter a valid [access code] which has the "System
] [6] [Walk Test
]. The