Maxwell MW-4042 Instruction Manual page 8

Сonvector
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 7
ENGLISH
Do not touch the power plug with wet hands.
Provide that the power cord does not contact
with hot surfaces and sharp furniture edges.
Do not wind the power cord around the unit body.
Check the cord insulation integrity periodically.
If the power cord is damaged, it should be
replaced by the manufacturer, a maintenance
service or similar qualified personnel to avoid
danger.
Do not attempt to repair the unit. Do not dis-
assemble the unit by yourself, if any malfunc-
tion is detected or after it was dropped, unplug
the unit and apply to any authorized service
center from the contact address list given in
the warranty certificate and on the website
www.maxwell-products.ru.
Transport the unit in the original package only.
Keep the unit out of reach of children and dis-
abled persons.
THIS UNIT IS INTENDED FOR HOUSEHOLD USE
ONLY. ITS COMMERCIAL USAGE AND USAGE
IN PRODUCTION AREAS AND WORK SPACES IS
PROHIBITED.
BEFORE THE FIRST USE
After unit transportation or storage at low tem-
perature keep it for at least three hours at room
temperature.
ATTENTION! Convector is intended only for addi-
tional heating of. It is not meant for operation as
main heating unit.
Unpack the unit.
Make sure that the operation mode switch (5) is
set to the position «0» (the unit is switched off).
SETTING
Option 1 – Stand mode
Turn the unit over. Combine openings on the
support plates (1) with wheels with relevant
openings in the lower part of the convectors
body (pic.1).
Fix the support plates (1) with wheels using
screws for fastening the support plates (pic. 2).
Turn the unit over and set it on the wheels.
Option 2 – Wall mounting
Attention! Before drilling a hole in the wall, make
sure that there is no electrical wiring at this place.
When mounting the unit on the wall, ensure that
the mains socket is below the level of the unit
and easy to access. Keep the following gaps:
between floor and unit – not less than 15 cm,
between front / upper panels and objects –
not less than 45 cm, between side panels and
objects – not less than 25 cm (pic. 7).
Support plates (1) with wheels are not used for
wall mounting of the convector.
First mark holes on the wall (pic. 3).
Drill the holes in the wall to the required depth.
Insert the dowels into the drilled holes (pic. 4)
and fix screws for mounting the convection fan
heater (pic. 5).
Hang the convector (pic.6) using wall brackets
(6) on the back side of the unit.
Using the convection fan heater
Before switching the unit on, make sure that
your home mains voltage corresponds to the
unit operating voltage, and the switch (5) is in
the position «0» (the unit is switched off).
Insert the power plug into the mains socket.
Select the required convection fan heater opera-
tion mode using the switch (5):
I – minimum heating power (1000 W),
II – maximum heating power (2000 W).
The indicator (3) will light up.
You may set the required room air heating level
from minimum to maximum value (MIN/MAX)
by turning the temperature control knob (4).
When the room temperature reaches the
required value, slowly turn the temperature con-
trol knob (4) counterclockwise until the indica-
tor (3) goes out. The preset temperature will be
maintained automatically. If the room temper-
ature is lower than the temperature set by the
temperature control knob (4), the unit will be
switched to the heating mode. When the preset
temperature is reached, the unit will be switched
to the standby mode, once the air in the room
cools down, the unit will be switched to the heat-
ing mode again.
To switch the unit off, set the temperature con-
trol knob (4) to the «MIN» position, set the
switch (5) to the «0» position and then unplug
the unit.
Notes:
While the first switching on the heating ele-
ment burns, therefore occurrence of a small
amount of smoke or foreign smell is possible.
It is normal.
Do not open windows and doors when the unit is
operating; otherwise you will not get the desired
results, due to cold air inflow.
WARNING! Do not cover the heater to avoid
overheating.
Automatic emergency switch-off functions
The unit is equipped with auto switch-off function in
case of overheating or if it is dropped.
If the unit starts overheating, the automatic ther-
mal switch will be on.
8

Advertisement

Table of Contents
loading