Download Print this page

Operation - U.S.SAWS HS100 Operating Manual

Hide thumbs Also See for HS100:

Advertisement

6.0
OPERATIONS
6.1
BEFORE OPERATING THE SAW
6.1.1
Be sure all nuts and bolts are tight.
6.1.2
Check the air supply for the correct pressure (90 PSI Min) and
rating (85 CFM Min).
6.1.3
Turn on air supply and check for leaks
6.1.4
Be sure to clean air hose to discharge any dirt, scale or
moisture(and do so before each use).
6.1.5
Connect the air hose and ensure proper couplings are usedon
air lines - typically no fitting is smaller than 1/2". Ensure the in-line oiler is
filled with pneumatic ice free oil.
6.2
WHILE OPERATING THE SAW
6.2.1
Before entering the blade into the material to be cut, squeeze
the trigger and allow the saw to reach full speed.
6.2.2
Ease the saw blade into the material to be cut.
6.2.3
At the end of the cut, lift the saw until the blade is clear of the
cut, then release the trigger.
6.2.4
Allow the blade to come to a complete stop before setting it
down.
6.2.5
Check the in-line oiler for oil level after 2-3 hours of operation.
6.2.6
When the rear wheel behind the blade needs to be moved so it
is not directly behind the blade, roll the saw onto it's side and remove the
"R" clip. Pull the axle out and retain the outboard position using the "R"
clip.
6.3
AFTER OPERATING THE SAW
6.3.1
Shut off air supply and disconnect from saw.
Remove the air line and fit a protective cover over the air inlet.
6.3.2
6.3.3
Clean the saw by removing all accumulated dust.
Give the grease fitting a couple shots of grease after every 40
6.3.4
hours of operation. (Gearbow saw only)
6.3.5
Pour a small amount of general purpose air tool oil into other
hose connector on the handle to flush out any moisture and lubricate the
motor.
6.4
INSTALLING OR REPLACING BLADE
6.4.1
Turn off and disconnect air supply and remove arbor nut (left-
hand thread) and outer flange from shaft
6.4.2
Place blade on shaft and check that the directional arrow points
clockwise as you turn the shaft (counterclockwise on up cut saws)
Install outer flange and lock gearbox with lock pin button under
6.4.3
gearbox. Tighten arbor bolt with wrench provided. Release gearbox lock
and spin blade to inspect blade rotation is smooth and straight.
O P E R AT I O N
Waterworks
Division
P: 866-987-7297 F: 813-621-7125
Visit us at www.ussaws.com
sales@ussaws.com
7

Advertisement

loading

This manual is also suitable for:

Hs-125Hs-150