Exhaust Air Management With Flexible Aluminium Hose; Shared Exhaust Air Ducts - Miele PDR 910 EL Installations Plan

Commercial tumble dryer
Hide thumbs Also See for PDR 910 EL:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 21
Exhaust air man-
agement with
flexible aluminium
hose
Shared exhaust
air ducts
Abluftführung mit Alu-Flex
Sie benötigen
 Wrap heat-resistant metallic tape around plug connections.
– den Adapter (liegt bei).
You will need
– Alu-Flex Abluftschlauch (nachkauf-
- the adapter (supplied).
bares Zubehör).
- Flexible aluminium exhaust air hose (optional accessory).
Install the adapter (1) and the flexible aluminium exhaust air hose
^ Installieren Sie den Adapter (1) und
(2).
den Alu-Flex Abluftschlauch (2).
,
Wrap heat-resistant metallic tape around plug connections.
Steckstellen müssen mit wärme-
festen Metallklebeband umwickelt
A shared exhaust air duct is only permitted in exceptional cases.
werden.
The shared exhaust air duct must be approved by the relevant
building inspector.
,
Sichern Sie den Trockner mit
 A non-return flap must be installed for each tumble dryer.
Spannlaschen gegen Verrutschen.
Otherwise, the tumble dryers may be damaged by a backflow of
condensation and their electrical safety could be affected.
If 3–5 tumble dryers are installed on one shared exhaust air duct,
the pipe diameter D must be increased.
Number of tumble dryers
3
4–5
en - Installation notes
Factor for increasing the pipe
diameters from Table II
1.25
1.5
27