First Time Lighting Instructions - Mendota AA-11-00712 Installation And Operating Instructions Manual

Direct vent gas fireplace heater
Table of Contents

Advertisement

5.4 First Time Lighting Instructions

Safety Information
Warning: If you do not
follow these instructions
exactly, a fire or
explosion may result
causing property
damage, personal injury,
and loss of life.
LIGHTING INSTRUCTIONS
IMPORTANT: Be sure all items on "INSTALLATION CHECK OFF LIST" (pg. 39 have been completed!
CAUTION: If the pilot goes out, be sure to wait a minimum of five minutes before relighting.
BE SURE TO ALWAYS REMOVE THE GLASS BEFORE RELIGHTING THE PILOT.
ALWAYS LIGHT PILOT WITH GLASS REMOVED!
1
Make sure any gas supply shut-off cocks are
open and Thermostat is "OFF".
2
Push in Gas Cock Dial Slightly and turn clockwise to
"OFF". NOTE: Dial cannot be turned from "PILOT" to
"OFF" unless dial is pushed slightly.
DO NOT FORCE!
3
Wait five (5) minutes to allow gas, which may have
accumulated in main burner compartment to escape.
If you smell gas, STOP.T
4
urn Gas Cock Dial Counterclockwise to "PILOT"
position.
5
Depress Gas Cock Dial and push in red Piezo igniter button. Once pilot ignites, continue depressing dial for about 1/2 minute.
If pilot does not remain ignited, repeat operation allowing a longer period before releasing Gas Dial.
IMPORTANT: After pilot is lit, system millivolt readings and gas pressure should be taken by qualified installer.
Pilot flame must register a minimum of 325 millivolt.
6
After pilot is lit and before installing logs, turn Gas Dial to "ON" and "cycle" the burner on/off to make certain it ignites
promptly and that the flame runs smoothly around burner curve and promptly lights entire burner.
7
With pilot operating, install log module and coals (see pg. 34-38). With logs/coals in place, "cycle" the burner again to make
sure of prompt ignition of burner and that the flame runs smoothly around entire burner and does not "lift off" burner.
NOTE: Logs will produce a strong, acrid odor on initial contact with flames (about 2 hrs.).
8
Reinstall glass front & screen.
9
Turn Gas Dial counterclockwise to "ON" then set Thermostat to turn on burner.
Main burner should now light IMMEDIATELY and flame should not "lift" off burner. If there is any delay in
ignition or if flame is "lifting off" burner, turn off burner and carefully check for proper installation of
logs/coals, vent system and proper pilot flame impingement on burner and thermopile. Logs or coals must
not block pilot flame or main burner flame. Vent system must be leak proof.
DO NOT PROCEED WITH OPERATION UNLESS BURNER "CYCLES" ON/OFF WITHOUT DELAYS!
85-03-01115
WHAT TO DO IF YOU SMELL GAS
Do not light any appliance.
Do not touch any light switch
Do not use any phone in your building.
Call your gas supplier from a neighbor's phone.
Follow the provider representative's instructions.
If you cannot reach your gas supplier, call the fire
department for assistance.