Advertisement

5.3.3 Group 2* - equipment Settings

* If Zoning is enabled, this group will be called Group 3.
MENU ITEM
Compressor Cooling Cycles Per Hour
1st Stage Compressor Cooling Cycles Per Hour
2nd Stage Compressor Cooling Cycles Per Hour 1
Compressor Heating Cycles Per Hour
1st Stage Compressor Heating Cycles Per Hour
2nd Stage Compressor Heating Cycles Per Hour 1
Indoor Heater Cycles Per Hour
1st Stage Indoor Heat Cycles Per Hour
2nd Stage Indoor Heat Cycles Per Hour
3rd Stage Indoor Heat Cycles Per Hour
1 Duty Cycles do not apply to second stage (variable range) of VSPD outdoor units

5.3.4 Group 3* - Sensor Settings

* If Zoning is enabled, this group will be called Group 4 .
MENU ITEM
Select Outdoor Temperature Sensor
Thermostat Humidity Sensor 1
Humidity Controlling Zone 2
1 This setting is only available when the onboard temperature sensor has been disabled
2 This setting is only available when zoning has been enabled and one or more 940's are being used as zone sensors
18-HD80D1-3-EN
OPTIONS
[DEFAULT]
2 - 6 Cph [3]
2 - 6 Cph [3]
2 - 6 Cph [3]
2 - 6 Cph [3]
2 - 6 Cph [3]
2 - 6 Cph [3]
2 - 6 Cph [5]
2 - 6 Cph [5]
2 - 6 Cph [5]
2 - 6 Cph [5]
OPTIONS [DEFAULT]
No ODT Sensor
Thermostat ODT Sensor
Communicating ODT Sensor
Relay Panel ODT Sensor
Enable, Disable
Select a zone
DESCRIPTION
Select # of cycles per hour during cooling operation
Select # of cycles per hour during 1st stage cooling operation
Select # of cycles per hour during 2nd stage cooling operation
Select # of cycles per hour during compressor heating operation
Select # of cycles per hour during 1st stage compressor heating
operation
Select # of cycles per hour during 2nd stage compressor heating
operation
Select # of cycles per hour during indoor heat operation
Select # of cycles per hour during 1st stage indoor heat operation
Select # of cycles per hour during 2nd stage indoor heat operation
Select # of cycles per hour during 3rd stage indoor heat operation
DESCRIPTION
Select the desired outdoor temperature sensor
Allows the user to re-enable the on-board humidity sensor of the
1050 when a wired sensor is being used in place of the on-board
temperature sensor of the 1050
Select which zone's humidity reading will be the humidity controlling
zone. Only zones which have a temperature/humidity sensor can be
selected
XL 1050
11