Sanyo SAP-K71GJA-S Technical & Service Manual page 11

Table of Contents

Advertisement

Indoor Unit
SAP – K91GJA
Part No.
Controls
Control circuit fuse
Remote Control Unit
Type
Number ... Dia. and length
Fan motor model ... Number
No. of poles ...50/60Hz rpm (High)
Nominal output
Coil resistance (Ambient temp. 20°C)
Safety
Type
devices
Operating temp.
Run capacitor
Type
Model
Rating
Coil resistance (Ambient temp. 25°C)
Coil
Rows
Fin pitch
Face area
mm
W
Open
°C
Close
µF
VAC
mm
2
m
8
POW–K91GJA
Microprocessor
250 V – 3.15 A
RCS–2S2E
Cross–flow
1 ... ø95 / L578
IBH-884-020 ... 1
2 ... 1,280/1,280
20
WHT – BRN : 201
WHT – VLT : 261
Thermal fuse
130
1.5
440
Stepping motor
MP24GA3
DC 12 V
A pair of each terminal: 380 ± 7%
Aluminum plate fin / Copper tube
2
1.4
0.110
DATA SUBJECT TO CHANGE WITHOUT NOTICE.

Advertisement

Table of Contents
loading

Table of Contents