Rinnai Demand Duo R-Series Installation And Operation Manual page 9

Hide thumbs Also See for Demand Duo R-Series:
Table of Contents

Advertisement

Product Number
Product Description
Installation Type
Minimum Gas Consumption Btu/hr (kW/hr)
Maximum Gas Consumption Btu/hr (kW/hr)
Tank Volume
First Hour Delivery at 100°F Rise
Temperature Setting
Product Weight
Noise level
Normal
Standby
System Electrical
Freeze Protection (tankless)
Data
Max Current
Fuse
Electric Connections
Bypass Flow Control
Gas Supply Pressure
Connections
Ignition System
Maximum Water Supply Pressure
Meets or exceeds energy efficiency requirements of ASHRAE 90.1b (current standard), C.E.C. Listed 80% Recovery
Efficiency.
Table 2: Recovery capacities with respect to temperature for 119 gallon storage tank
Tank Capacity
119
U.S.
CHS199100RECiN/
Gals.
CHS199100RECiP
450
Liters
Demand Duo™ R-Series (REC) Installation and Operation Manual
CHS199100RECiN
4.0 in. wc - 10.5 in. wc
RECOVERY CAPACITIES
U.S. GALLON/HR LITERS/HR AT TEMPERATURE RISE INDICATED
°F
30°F
40°F
50°F
°C
17°C
22°C
28°C
GPH
643
482
386
LPH 2,435 1,826 1,461 1,217 1,044
Automatic Circulating Tank Water Heater
Indoor
11,900 (3.5)
199,000 (58.3)
119 Gallons (450 Liters)
276 Gallons (1046 Liters)
120°F (49°C) to 180°F (82°C)
364 lbs. (165kg)
54 dB
236 W
1 W
226 W
9.0 A
Tankless Engine - 10 A
Appliance: AC 120 Volts, 60Hz.
Bypass Servo Control
Natural Gas:
Gas Supply Inlet - 3/4 in. MNPT
Hot Water Outlet - 1-1/2 in. MNPT
Cold Water Inlet - 1-1/2 in. MNPT
Direct Electronic Ignition
150 PSI
60°F
70°F
80°F 90°F 100°F 110°F 120°F 130°F 140°F
33°C
39°C 44°C 50°C 56°C
322
276
241
214
913
812
CHS199100RECiP
Propane:
8.0 in. wc - 13.5 in. wc
61°C
67°C
72°C
193
175
161
148
730
664
609
562
78°C
138
522
9