5. Strip the green, white, and black field
supplied wires 1/2 in. Make sure the
conductors are completely bare (Figure 25).
Figure 25
Match the wire colors, then grip the wire
6.
firmly and push the conductor into open
port of the push in connector (Figure 26).
NOTE
Use only one conductor per port. Verify
conductor is fully inserted to the back of
the connector.
Figure 26
30
A manual gas control valve is placed in the
gas line to the water heater.
Check the gas lines and connections for
leaks.
Confirm that the gas inlet pressure is within
limits.
Confirm that the water heater is rated for the
gas type supplied.
Confirm that the electricity is supplied from a
120 VAC, 60 Hz power source and is in a
properly grounded circuit.
Confirm that an extension cord or an adapter
plug has NOT been used with the water
heater.