Rinnai Demand Duo R-Series Installation And Operation Manual page 46

Hide thumbs Also See for Demand Duo R-Series:
Table of Contents

Advertisement

To Display Performance Data
1. Press and hold the (Down) button.
2. While holding the (Down) button for 2 seconds, press and hold the "On/Off" button (hold both
buttons simultaneously) (Figure 43)
3. Use the (Up) and (Down) buttons to scroll to the desired information described in Table 11:
Performance Data Table.
4. To exit performance data, repeat step 2 above.
5. When complete, the set temperature appears in the display.
Table 11: Performance Data
No.
01
02
03
04
05
06
07
08
09
11
12
19
20
30
31
46
Figure 43
Data
Water Flow Rate
Outgoing Temperature
Combustion Hours
Combustion Cycles
Fan Frequency
Additional Controllers Connected
Water Flow Control Position
Inlet Thermistor Temperature
Fan Current
HEX Outlet Temperature
Bypass Flow Control Position
Pump Hours
Pump Cycles
Upper Tank Thermistor Temperature
Lower Tank Thermistor Temperature
Demand Duo™ R-Series (REC) Installation and Operation Manual
Unit
0.1gal/min
°F
x100 Hours
*
Hz
*
0=Mid, 1=Open, 2=Closed
°F
10mA
°F
Degrees of opening
x100 Hours
*
°F
°F