For each of the heat pumps present, it is possible to select the
parameters described below:
– "DHW aux heat source activation logic": the param-
eter allows to choose when to activate the secondary
heat source (heating elements, if enabled or present,
or an auxiliary heat source) of the heat pump in DHW
mode.
– In case of a heat pump malfunction and for heat
production integration ("Heat integr. and backup"):
the secondary heat source is activated both to inte-
grate domestic hot water at the heat pump and in
case of a heat pump malfunction.
– Only in case of a heat pump malfunction ("HP fail-
ure backup"): the secondary heat source is activated
only in case of a heat pump malfunction.
– "DHW operation mode": refer to the paragraph "Heat
Pump".
Energy manager slave 1
DHW aux heat source activation
logic
DHW operation mode

2.11.11 Photovoltaic integration

This menu is available for products that are configured for in-
tegration with a photovoltaic system (heating/cooling, hybrid,
DHW heat pumps) and that manage a DHW storage tank with
a temperature sensor.
– "PV offset DHW setpoint temperature": if a heating
heat pump or a hybrid system is installed, the param-
eter sets the degrees to be added to the temperature
set-point for DHW storage tank charge when additional
electrical energy is available from the photovoltaic sys-
tem.
– "PV setpoint temperature": if a DHW heat pump is
installed, the parameter sets the temperature set-point
for DHW storage tank charge when additional electrical
energy is available from the photovoltaic system.
52 / EN
Heat integr. and backup
HC - HP 40
Fig. 81
In case of heat pump cascades, the parameter "PV offset DHW
setpoint temperature" for individual heat pumps that manage
a DHW storage tank with a temperature sensor can be set with-
in the relative sections.
Photovoltaic integration
Energy manager slave
Energy manager slave
Energy manager slave 1
Energy manager slave 2
Energy manager slave 3
Energy manager slave 4
Energy manager slave 5

2.11.12 System measurement unit

This parameter sets the unit of measurement (international sys-
tem or USA system)
Advanced settings
Cooling settings
AUTO function
System measurement unit
Time Program mode
Room temperature correction
Zones selection
User Menu
>
Fig. 82
>
>
>
>
>
Fig. 83
International system
USA system
Fig. 84