– "Set curve slope": if the automatic temperature con-
trol function ("AUTO function") is active, the slider can
be used to change the slope of the climate curve. Con-
sult the manual of the heat generator installed in the
system for further information.
Zone 1 parameters
T set Z1
Set curve slope
Set curve slope
-
1,5
Push Ok to confirm
– "Automatic winter mode": allows to adjust the heat
request according to the outdoor temperature. In order
to enable this function, an outdoor temperature sensor
must be fitted in the system or, if available, the "Internet
weather report" function must be active (refer to the
"Connectivity" paragraph). The function can be activat-
ed for each zone of the system.
Zone 1 parameters
Automatic winter mode
activation
Automatic winter mode
threshold
Automatic winter mode delay
time
– "Automatic winter mode activation": allows for acti-
vating the function.
– "Automatic winter mode threshold": allows for set-
ting the outdoor temperature threshold above which
the zone's heat request is inhibited.
– "Automatic winter mode delay time": the heat re-
quest is inhibited if the outdoor temperature stays
above the threshold for a minimum time defined by the
parameter.
48 / EN
2.11.2
>
>
Fig. 69
+
Fig. 70
OFF
20°C
300 min
2.11.3
This function calculates the water temperature set-point in
heating and/or cooling mode for each zone according to the
type of temperature control set (technical menu) and the tem-
Fig. 71
perature sensors (room temperature sensor and/or outdoor
temperature sensor – if present).

Cooling settings

– "Cooling setpoint temp": in the menu you can set
the water temperature set-point in cooling mode for
each hydraulic zone present in the system. The menu
can be used to:
– Adjust the temperature set-point if the automatic
temperature control function ("AUTO function") is
disabled.
– Apply a correction to the temperature set-point us-
ing a slider, if the "AUTO" function is active and the
water temperature does not match the desired tem-
perature.
– "Set curve slope": if the automatic temperature con-
trol function ("AUTO function") is active, the slider can
be used to change the slope of the climate curve. Con-
sult the manual of the heat generator installed in the
system for further information.
Zone 1 parameters
T set Z1
Set curve slope
Set curve slope
-
1,5
Push Ok to confirm

AUTO function

User Menu
>
>
Fig. 72
+
Fig. 73