Buffer Tank; Heat Pump - Ariston SENSYS HD Manual

Table of Contents

Advertisement

2.11.4

Buffer tank

Buffer
Buffer activation
Buffer comfort setpoint heating
Reduced Setpoint heating
Buffer comfort setpoint cooling
Reduced Setpoint cooling
Buffer setpoint mode
Buffer
Buffer setpoint mode
Control mode
This function is available only if the system is fitted with a tech-
nical water storage tank (buffer) for heating and/or cooling.
– "Buffer activation": allows to enable/disable the buff-
er charge.
– "Buffer comfort setpoint heating": sets the desired
buffer charge temperature in heating mode for the
comfort slot.
– "Reduced Setpoint heating": sets the desired buffer
charge temperature in heating mode for the reduced
slot.
– "Buffer comfort setpoint cooling": sets the desired
buffer charge temperature in cooling mode for the
comfort slot.
– "Reduced Setpoint cooling": sets the desired buffer
charge temperature in cooling mode for the reduced
slot.
– "Buffer setpoint mode": sets the buffer charge mode.
– "Fixed": the buffer charge temperature is defined
in the parameters shown above.
– "Variable": the buffer charge temperature is calcu-
lated according to the automatic temperature con-
trol function (if active).
– "Control mode": setting of the buffer charge operat-
ing mode ("Disabled"/"Time Based"/"Always active")
2.11.5
This menu is available only if a heat pump with the heating/
cooling functions is installed. For further information, see the
product manual.
OFF
40 °C
20 °C
18 °C
23 °C
Fixed
Fig. 74
Fixed
Always active
a
Fig. 75

Heat Pump

Heat Pump
Quiet mode
CH aux heat source activation
logic
DHW aux heat source
activation logic
DHW operation mode
– "Quiet mode": the following settings allow for reduc-
ing the noise level of the heat pump by limiting the
compressor frequency.
Activating this function may reduce the ma-
chine's performance.
– "Quiet mode activation HHP": enables/disables
the silent mode.
– "Quiet mode start time HHP [hh:mm]": sets the
time for the machine to start working in silent mode.
– "Quiet mode end time HHP [hh:mm]": sets the
time for the machine to stop working in silent mode.
– "CH aux heat source activation logic": the param-
eter allows to choose when to activate the secondary
heat source (heating elements, if enabled or present, or
an auxiliary heat source) of the heat pump in heating
mode.
– In case of a heat pump malfunction and for heat
production integration ("Heat integr. and backup"):
the secondary heat source is activated both to inte-
grate heating at the heat pump and in case of a heat
pump malfunction.
– Only in case of a heat pump malfunction ("HP fail-
ure backup"): the secondary heat source is activated
only in case of a heat pump malfunction.
– "DHW aux heat source activation logic": the param-
eter allows to choose when to activate the secondary
heat source (heating elements, if enabled or present,
or an auxiliary heat source) of the heat pump in DHW
mode.