RenewAire DN Series Instruction Manual

RenewAire DN Series Instruction Manual

Dedicated outdoor air system
Table of Contents

Advertisement

Quick Links

DN SERIES DOAS
Shipping, Rigging, Hoisting, and Assembly Manual
DN2
DN3
DN5
Indoor Model DN2IN Shown
Outdoor Model DN3RT Shown

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DN Series and is the answer not in the manual?

Questions and answers

Summary of Contents for RenewAire DN Series

  • Page 1 DN SERIES DOAS Shipping, Rigging, Hoisting, and Assembly Manual Indoor Model DN2IN Shown Outdoor Model DN3RT Shown...
  • Page 2 DOAS DN-Series WARNING NOTICE RISK OF DEATH 0R SERIOUS INJURY Risk of DAMAGE TO ENTHALPIC CORES Hoisting heavy equipment overhead is inherently dangerous. Whenever working within the DOAS cabinet, protect the enthal- Failure to properly rig the DOAS for hoisting or the use of in- pic cores from accidental damage.
  • Page 3 DN-Series DOAS READ AND SAVE THIS MANUAL/LIRE ET CONSERVER CE MANUEL UNIT INFORMATION In the unlikely event that factory assistance is ever required, information located on the unit label will be needed. OPTION CODE: SERIAL NUMBER: SO #: UNIT INFORMATION UNIT LABEL (TYPICAL) 1.800.627.4499...
  • Page 4: Table Of Contents

    TABLE OF CONTENTS DOAS DN-Series 1.0 OVERVIEW 3.0 INSTALLATION PREPARATION 3.1 DRAIN TRAP PREPARATION ........32 2.0 SHIPPING/RECEIVING/HANDLING 3.2 UNIT STORAGE ............ 32 2.1 OFF-LOADING ............7 3.3 ROOFTOP CURBS ..........32 2.2 FORKLIFT USE ............7 3.4 CURB CLIPS ............32 2.3 HOISTING ..............
  • Page 5 TABLE OF CONTENTS DN-Series DOAS TABLE OF ILLUSTRATIONS Figure 2.3.0 Example of Minimum Hoisting Requirements ..............9 Figure 3.4.0 Curb Clips Typical Installation ..................32 Figure 3.9.0 Outside Air Hood (Typical) .....................34 Figure 3.9.1 Exhaust Air Hood (Typical) .....................34 Figure 3.10.0 Piping Penetrations Drawing A ..................35 Figure 3.10.1 Piping Penetrations Drawing B ..................35 1.800.627.4499...
  • Page 6: Overview

    The base also has openings to permit use of a forklift with extended forks to lift the unit from either the sides or the ends. RenewAire DOASs come in two different versions, either the Indoor Series or the Rooftop Series. Rooftop Series can have the Packaged Refrigeration option. Each series is available in three different sizes (DN2, DN3, DN5) but they may also be configured at the factory into a shorter unit with limited options.
  • Page 7: Shipping/Receiving/Handling

    Note that when the shipment is delivered, the shipment MUST BE INSPECTED for any shipping damage or missing items. If any damage is found or if items are missing, notify your RenewAire dealer before accepting the shipment. If damage is found, take digital pictures of the damage.
  • Page 8: Hoisting

    Do not lift in high winds. RenewAire will not be responsible for any damage during the rigging, lifting, or installing of the DOAS. Refer to Center of Gravity drawings in Section 4.0 of this manual for approximate center of gravity and all corner weights.
  • Page 9: Figure 2.3.0 Example Of Minimum Hoisting Requirements

    HOISTING SLINGS (TYPICAL) FIGURE 2.3.0 EXAMPLE OF MINIMUM HOISTING REQUIREMENTS IT IS THE INSTALLING CONTRACTOR’S RESPONSIBILITY TO PROPERLY RIG AND HOIST THE UNIT. RENEWAIRE DOES NOT GIVE SPECIFIC INSTRUCTIONS FOR PROPER RIGGING BECAUSE ALL JOB SITES ARE DIFFERENT. (800) 627- 4499 support@renewaire.com...
  • Page 10: Dn2In Drawings

    SHIPPING/RECEIVING DOAS DN-Series 2.4 DN2IN DRAWINGS 2.4.1 DN2IN Dimensioned Drawing 1.800.627.4499...
  • Page 11: Dn2In Center Of Gravity Drawing

    SHIPPING/RECEIVING DN-Series DOAS 2.4.2 DN2IN Center of Gravity Drawing 1.800.627.4499...
  • Page 12: Dn2Rt Drawings

    SHIPPING/RECEIVING DOAS DN-Series 2.5 DN2RT DRAWINGS 2.5.1 DN2RT Dimensioned Drawing 1.800.627.4499...
  • Page 13: Dn2Rt Center Of Gravity Drawing

    SHIPPING/RECEIVING DN-Series DOAS 2.5.2 DN2RT Center of Gravity Drawing 1.800.627.4499...
  • Page 14: Dn2Rt With Packaged Refrigeration Dimensioned Drawing

    SHIPPING/RECEIVING DOAS DN-Series 2.5.3 DN2RT with Packaged Refrigeration Dimensioned Drawing 1.800.627.4499...
  • Page 15: Dn2Rt With Packaged Refrigeration Center Of Gravity Drawing

    SHIPPING/RECEIVING DN-Series DOAS 2.5.4 DN2RT with Packaged Refrigeration Center of Gravity Drawing 1.800.627.4499...
  • Page 16: Dn2Rt Full-Sized Curb Drawing

    CURB SUPPLIED WITH 52 FT OF 1 1/2" X 1/4" GASKETING FROM THE CURB MANUFACTURER. TOLERANCE: +/- 1/16" PER PIECE. ISOMETRIC VIEW SCALE 1/34 201 Raemisch Rd. RenewAire LLC UNLESS OTHERWISE SPECIFIED, Waunakee, WI 53597 USA DIMENSIONS ARE IN INCHES. TEL: (608) 221-4499 TOLERANCES: FAX: (608) 221-2824...
  • Page 17: Dn3In Drawings

    SHIPPING/RECEIVING DN-Series DOAS 2.6 DN3IN DRAWINGS 2.6.1 DN3IN Dimensioned Drawing 1.800.627.4499...
  • Page 18: Dn3In Center Of Gravity Drawing

    SHIPPING/RECEIVING DOAS DN-Series 2.6.2 DN3IN Center of Gravity Drawing 1.800.627.4499...
  • Page 19: Dn3Rt Drawings

    SHIPPING/RECEIVING DN-Series DOAS 2.7 DN3RT DRAWINGS 2.7.1 DN3RT Dimensioned Drawing 1.800.627.4499...
  • Page 20: Dn3Rt Center Of Gravity Drawing

    SHIPPING/RECEIVING DOAS DN-Series 2.7.2 DN3RT Center of Gravity Drawing 1.800.627.4499...
  • Page 21: Dn3Rt With Packaged Refrigeration Dimensioned Drawing

    SHIPPING/RECEIVING DN-Series DOAS 2.7.3 DN3RT with Packaged Refrigeration Dimensioned Drawing 1.800.627.4499...
  • Page 22: Dn3Rt With Packaged Refrigeration Center Of Gravity Drawing

    SHIPPING/RECEIVING DOAS DN-Series 2.7.4 DN3RT with Packaged Refrigeration Center of Gravity Drawing 1.800.627.4499...
  • Page 23: Dn3Rt Full-Size Curb Drawing

    CURB SUPPLIED WITH 72 FT OF 1 1/2" X 1/4" GASKETING FROM THE CURB MANUFACTURER. TOLERANCE: +/- 1/16" PER PIECE. 201 Raemisch Rd. RenewAire LLC UNLESS OTHERWISE SPECIFIED, Waunakee, WI 53597 USA DIMENSIONS ARE IN INCHES. TEL: (608) 221-4499 TOLERANCES:...
  • Page 24: Dn5In Drawings

    SHIPPING/RECEIVING DOAS DN-Series 2.8 DN5IN DRAWINGS 2.8.1 DN5IN Dimensioned Drawing 1.800.627.4499...
  • Page 25: Dn5In Center Of Gravity Drawing

    SHIPPING/RECEIVING DN-Series DOAS 2.8.2 DN5IN Center of Gravity Drawing 1.800.627.4499...
  • Page 26: Dn5Rt Drawings

    SHIPPING/RECEIVING DOAS DN-Series 2.9 DN5RT DRAWINGS 2.9.1 DN5RT Dimensioned Drawing 1.800.627.4499...
  • Page 27: Dn5Rt Center Of Gravity Drawing

    SHIPPING/RECEIVING DN-Series DOAS 2.9.2 DN5RT Center of Gravity Drawing 1.800.627.4499...
  • Page 28: Dn5Rt With Packaged Refrigeration Dimensioned Drawing

    SHIPPING/RECEIVING DOAS DN-Series 2.9.3 DN5RT with Packaged Refrigeration Dimensioned Drawing 1.800.627.4499...
  • Page 29: Dn5Rt With Packaged Refrigeration Center Of Gravity Drawing

    SHIPPING/RECEIVING DN-Series DOAS 2.9.4 DN5RT with Packaged Refrigeration Center of Gravity Drawing 1.800.627.4499...
  • Page 30: Dn5Rt Full-Size Curb Drawing

    CURB SUPPLIED WITH 92 FT OF 1 1/2" X 1/4" GASKETING FROM THE CURB MANUFACTURER. TOLERANCE: +/- 1/16" PER PIECE. 201 Raemisch Rd. RenewAire LLC UNLESS OTHERWISE SPECIFIED, Waunakee, WI 53597 USA DIMENSIONS ARE IN INCHES. TEL: (608) 221-4499 ISOMETRIC VIEW...
  • Page 31 DN-Series DOAS T H I S P A G E I S I N T E N T I O N A L LY L E F T B L A N K . 1.800.627.4499...
  • Page 32: Installation Preparation

    3.4 CURB CLIPS RenewAire offers optional curb clip kits for the DN-Series. The Curb Clip Kits are designed for winds up to 90 MPH. The available curb clip kits include clips and hardware. Clips must be installed per the instructions before the DN unit is placed on the curb, using the supplied hardware.
  • Page 33: Equipment Rails

    The unit should be hoisted into position directly above the curb or its intended location and lowered straight down onto its bearing surface. If the unit is being placed on a RenewAire curb, foam gasketing is to have been applied to the bearing surfaces. The foam gasketing can be damaged by lateral adjustments.
  • Page 34: Installation Of Hoods

    INSERTION FLANGE OA HOOD (TYPICAL) FIGURE 3.9.0 OUTSIDE AIR HOOD (TYPICAL) www.renewaire.com (800) 627- 4499 support@renewaire.com Slide the top flange of the OA hood beneath the roof panel side trim. Reinstall the screws at the top of the roof flange and then install screws along the sides and lower edge of the hood.
  • Page 35: Figure 3.10.0 Piping Penetrations Drawing A

    Do not damage electrical wiring or other hidden utilities or structures. Units with gas heat have connections out the front of the unit. For additional information see DN Series DOAS Indoor Installation, Operation and Maintenance Manual, DN Series DOAS Rooftop Installation, Operation and Maintenance Manual, and DN Refrigerant Supplement.
  • Page 36 About RenewAire For over 35 years, RenewAire has been a pioneer in enhancing indoor air quality (IAQ) in commercial and residential buildings of every size. This is achieved while maximizing sustainability through our fifth-generation, static-plate, enthalpic-core Energy Recovery Ventilators (ERVs) that optimize energy efficiency, lower capital costs via load reduction and decrease operational expenses by minimizing equipment needs, resulting in significant energy savings.

Table of Contents