Minimum Clearances to Combustibles

The clearances listed below are minimum distances unless otherwise stated.
A major cause of fires is failure to maintain required clearances (air space) to combustible materials. It is of the greatest importance that this decorative
gas appliance is installed only in accordance with these instructions.
Clearance:
A: Sidewall
B: Ceiling
D: Min. Hearth Depth
E: Min. Hearth Length
J***
K: Min. Alcove Width
L: Max. Alcove Depth
M: Mantel Deflector
• A 36" (914 mm) wide x 12" (305 mm) deep, non-combustible hearth
is required in front of the appliance unless the unit is raised 3" (76 mm) off the floor.
• *An optional 2-1/2" (64 mm) mantel deflector reduces the mantel height to 13" (330 mm) from top of the unit @ 1" (25 mm) depth.
• (J): *** Measurement from the faceplate edge or doors - for reference only: 27-1/4'' (692 mm)
B
D
Dimension
8" / 203 mm
63-3/4" / 1873 mm
12" / 305 mm
36"/ 914 mm
27-1/4" / 692 mm
54" / 1372 mm
36" / 914 mm
2-1/2"/ 89 mm*
J***
E
K
Diagram 1
Measured From:
***From inside edge of faceplate / doors
From base of unit
Not required if unit raised 3" (76 mm) off the floor.
Not required if unit raised 3" (76 mm) off the floor.
inside edge of the faceplate/doors - reference only.
From the front of the unit.
A
L
Gi29L Gas Insert
|
3