Energy Management System - Mennekes AMTRON Compact 2.0s 11 Operating And Installation Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 45
n The Sun button has no function unless
solar charging has been set up.
The following information applies to both
the 22 kW and 11 kW variants with enabled
dynamic phase switchover:
n Switching between Standard mode, Sun-
shine mode and Sunshine+ mode is al-
ways possible (also while charging is in
progress).
The following information applies to the
11 kW variant with disabled dynamic phase
switchover:
n Switching between Sunshine mode and
Sunshine+ mode is always possible (also
while charging is in progress).
n Switching between Standard mode and
Sunshine(+) mode is not possible while
charging is in progress. The vehicle must
be disconnected from the charging sta-
tion before switchover.

6.2.4 Energy management system

The tasks described in this section may only
be carried out by a qualified electrician.
The product can be connected to an energy man-
agement system via Modbus RTU as needed to
complete complex application cases. The product is
controlled by the energy management system
(master).
Information on compatible energy manage-
ment systems and the description of the
Modbus RTU interface (Modbus RTU Re-
gister Table) can be found on our website:
www.mennekes.org/emobility/knowledge/
compatible-systems-and-interfaces
28