Motrona touchMATRIX PN350 Operating Manual

Motrona touchMATRIX PN350 Operating Manual

Profinet display device with touch screen and graphic display

Advertisement

Quick Links

Operating Manual
PROFINET display device with touch screen and graphic display
Product features:
Multi-function display with PROFINET interface
Operating modes for displaying two process values and links of the two values
(1+2, 1-2, 1x2, 1:2)
PROFINET IO Device Conformance Class B
Dual Port Ethernet with integrated switch
Bright and high-contrast display with event dependent color variations
Emulation of a 7-segment display inclusively icons and units
Intuitive and easy parameterization by plain text and touch screen
3.78 x 1.89 inch (96 x 48 mm) norm panel housing and IP65 protection
Optional switching outputs
Available options:
PN350:
Basic unit with PROFINET-interface
Option AC:
Option AO:
Option AR:
Option CO:
Option CR:
Option RL:
Options can be combined
motrona GmbH, Zeppelinstraße 16, DE - 78244 Gottmadingen, Tel. +49 (0) 7731 9332-0, Fax +49 (0) 7731 9332-30, info@motrona.de, www.motrona.de
touchMATRIX
Power supply 115 ... 230 VAC
16 bit analog output, 4 control outputs, serial RS232 interface
16 bit analog output, 4 control outputs, serial RS485 interface
4 control outputs, serial RS232 interface
4 control outputs, serial RS485 interface
2 relay outputs
Indicator PN350
®

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the touchMATRIX PN350 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Motrona touchMATRIX PN350

  • Page 1 4 control outputs, serial RS232 interface • Option CR: 4 control outputs, serial RS485 interface • Option RL: 2 relay outputs Options can be combined motrona GmbH, Zeppelinstraße 16, DE - 78244 Gottmadingen, Tel. +49 (0) 7731 9332-0, Fax +49 (0) 7731 9332-30, info@motrona.de, www.motrona.de...
  • Page 2 First Version Legal notices: All contents included in this manual are protected by the terms of use and copyrights of motrona GmbH. Any reproduction, modification, usage or publication in other electronic and printed media as well as in the internet requires prior written authorization by motrona GmbH.
  • Page 3: Table Of Contents

    Table of Contents Safety Instructions and Responsibility ................5 General Safety Instructions ......................5 Use According to the Intended Purpose ..................5 Installation ............................6 EMC Guidelines ..........................7 Cleaning, Maintenance and Service Notes..................7 Introduction ........................8 Operation Mode ..........................8 Function Diagram ..........................
  • Page 4 Variables (Actual values): ......................46 Dimensions ............................ 47 Technical Specifications ........................ 48 Pn350_01a_oi_e.docx / Mai-23 Seite 4 / 49...
  • Page 5: Safety Instructions And Responsibility

    Safety Instructions and Responsibility General Safety Instructions This operation manual is a significant component of the unit and includes important rules and hints about the installation, function and usage. Non-observance can result in damage and/or impairment of the functions to the unit or the machine or even in injury to persons using the equipment! Please read the following instructions carefully before operating the device and observe all safety and warning instructions! Keep the manual for later use.
  • Page 6: Installation

    Installation The device is only allowed to be installed and operated within the permissible temperature range. Please ensure an adequate ventilation and avoid all direct contact between the device and hot or aggressive gases and liquids. Before installation or maintenance, the unit must be disconnected from all voltage-sources. Further it must be ensured that no danger can arise by touching the disconnected voltage-sources.
  • Page 7: Emc Guidelines

    Run signal and control cables apart from power lines and other cables emitting electromagnetic • noise. Please also refer to motrona manual “General Rules for Cabling, Grounding, Cabinet Assembly”. You can download that manual by the link https://www.motrona.com/en/support/general-certificates.html Cleaning, Maintenance and Service Notes To clean the front of the unit please use only a slightly damp (not wet!), soft cloth.
  • Page 8: Introduction

    Introduction This series of display unit is suitable for PROFINET and panel mounting. Two process data values transmitted by the PROFINET controller can be scaled, linked and displayed. Due to the intuitive operation, the extensive functions and options, it can be used universally. Basic knowledge of the function of PROFINET IO is required to commission the PROFINET display device and to understand these operating instructions.
  • Page 9: Function Diagram

    Function Diagram Pn350_01a_oi_e.docx / Mai-23 Seite 9 / 49...
  • Page 10: Electrical Connections

    Electrical Connections The terminal screws should be tightened with a slotted screwdriver (blade width 2mm). DC Power Supply The unit accepts DC supply from 18 to 30 V at the terminals 1 and 2. The power consumption depends on the level of the supply voltage with approx. 100 mA and the additional current required at the Auxiliary Voltage Output.
  • Page 11: Profinet Interface

    These LEDs are not necessary for normal operation but may be helpful during commissioning. PROFINET-Configuration The PROFINET interface is described in the corresponding GSDML file "GSDML-V2.43-MOTRONA- PN350-REPNS-xxxxxxxx". The device has one single slot, to which the "PN350" module is dedicated. The module has a single subslot with a fixed submodule.
  • Page 12: Process Data

    Process Data With the cyclic PROFINET communication, the PROFINET IO controller sends 9 bytes of process output data to the PN350: • Process Data Value 1, 4 bytes • Process Data Value 2, 4 bytes • Output Set Value, 1 byte Process Data Value 1 and Process Data Value 2 can be scaled and provided with units using the parameters in the "Fieldbus Properties"...
  • Page 13: Control Inputs

    Control Inputs Five control inputs with HTL-PNP characteristics are available at terminals 5, 7, 10, 11 and 12 Three of these inputs (Ctrl.In 1…3) are configurable in the COMMAND MENU and can be used for externally triggered functions such as switching the display, locking the touch screen or enabling the latching of control and relay outputs.
  • Page 14: Serial Interface (Option Ao/Ar/Co/Cr)

    Serial Interface (Option AO/AR/CO/CR) A serial interface (RS232 or RS485) is available at terminal 16, 17 und 18. This interface can be configured in the SERIAL MENU. The serial interface RS232 or RS485 can be used: • for easy setup and commissioning of the units •...
  • Page 15: Ac Power Supply (Option Ac)

    Wiring of the control outputs: AC Power Supply (Option AC) The unit accepts AC supply from 115 to 230 V at the terminals 24 and 25. The power consumption depends on the level of the supply voltage with approx. 3VA and the additional current required at the auxiliary voltage output.
  • Page 16: Display And Touch Screen

    Display and Touch Screen Screen Structure for Parameterization The parameter menus and the parameters are described in chapter 5. Start setup procedure: To edit the parameters, press the touch screen for 3 seconds. Menu selection: Select the parameter menu via arrow buttons and confirm with “OK”.
  • Page 17: Screen Structure In Operation

    Screen Structure in Operation During operation, either the two process data values and/or the linked value can be displayed. The values to be displayed are selected in the display menu. The following displays are available: Display of a value with unit and status bar To switch to the next display, press the touch screen.
  • Page 18: Error Messages

    Continuation “Screen Structure in Operation“: Display for quick start for enter preselection values (PRESELECTION VALUES) To switch to the next display, press the top of the screen or “SKIP”. This is only possible with option CO, CR, AO, AR or RL. Display with minimum and maximum values To switch to the next display, press the top of the screen or “SKIP”.
  • Page 19 Continuation “Error Messages“: ERROR: LARGE DI. OUT OF RANGE The value range of the large display has been exceeded All error messages are displayed flashing. A corresponding diagnostic alarm is sent via PROFINET for each error message The error messages described are automatically reset as soon as the corresponding display value is back in the displayable range.
  • Page 20: Parameter / Overview - Menu Structure

    Parameter / Overview – Menu Structure The parameterization of the device is realized via the serial interface with a PC and the operating software OS. The link to the free download can be found on page 2. This section provides an overview of the menus and their parameters. The menu names are printed bold and the associated parameters are listed under the menu name.
  • Page 21 Continuation “Parameter / Overview – Menu Structure” Menu / Parameter Menu / Parameter PRESELECTION 4 MENU DISPLAY MENU SOURCE 4 START DISPLAY MODE 4 SOURCE SINGLE HYSTERESIS 4 SOURCE DUAL TOP PULSE TIME 4 SOURCE DUAL DOWN OUTPUT TARGET 4 LARGE DISPLAY OUTPUT POLARITY 4 COLOR...
  • Page 22: General Menu

    General Menu In all parameter tables, the values with a gray background are the default values (factory settings) of the respective parameter. OPERATIONAL MODE This parameter defines how the linked display value is calculated. VALUE1 + VALUE2 The linked value is the sum of the two process data values VALUE1 –...
  • Page 23: Fieldbus Properties

    Fieldbus Properties The parameters for displaying the process data values are set in this menu. IN1 FACTOR (Multiplication factor for process data value 1) This parameter defines the factor by which the process data value 1 is multiplied. -99999999 Smallest value Default value 99999999 Highest value...
  • Page 24 Continuation “Fieldbus Properties“: IN 1 SCALE UNIT (Unit of measure for process data value 1) This parameter defines which unit is shown for the process data value 1 in the display. The setting of the SCALE UNITS does not affect the displayed value. Default m/min km/h...
  • Page 25 Continuation “Fieldbus Properties“: IN2 FACTOR (Multiplication factor for process data value 2) This parameter defines the factor by which the process data value 2 is multiplied. -99999999 Smallest value Default value 99999999 Highest value IN2 DIVIDER (Division factor for process data value 2) This parameter defines the divisor by which the process data value 2 is divided.
  • Page 26 Continuation “Fieldbus Properties“: FB VALUE IN 1 * Reserved for future use, must remain set to the default value. Smallest value Default value Highest value FB VALUE IN 2 * Reserved for future use, must remain set to the default value. Smallest value Default value Highest value...
  • Page 27: Linkage Properties

    Linkage Properties The parameters for displaying the linked display value are set in this menu FACTOR (Multiplication factor) This parameter defines the factor by which the result of the link is multiplied. -99999999 Smallest value Default value 99999999 Highest value DIVIDER (Division factor) This parameter defines the divisor by which the result of the link is divided.
  • Page 28: Preselection Values

    Preselection Values This menu is used to set the preselection values or the switching points. The preselection values are always referred to the selected SOURCE of the PRESELECTION MENU. This menu is only available for devices with option CO, CR, AO, AR or RL. PRESELECTION 1 Preselection / switching point 1 -99999999...
  • Page 29: Preselection 1 Menu

    Preselection 1 Menu In this menu, the parameters of the reference source, the switching conditions and further definitions for preset value / switching point 1 are defined. This function is only available for devices with option CO, CR, AO, AR or RL. SOURCE 1 This parameter defines the reference source for preselection 1 FIELDBUS VALUE 1...
  • Page 30 Continuation “Preselection 1 Menu“: HYSTERESIS 1 This parameter defines the switching hysteresis of the switch-off point for preselection 1 No switching hysteresis … 9999 Switching hysteresis of 99999 PULSE TIME 1 (S) Duration of output pulse for the switching condition of preselection 1. 0.000 No output pulse (static signal) …...
  • Page 31: Preselection 2 Menu

    Continuation “Preselection 1 Menu“: EVENT COLOR 1 Event-depending change of the display color for the switching condition of preselection 1. EVENT COLOR 1 has the lowest priority. EVENT COLOR 2 … 4 are allowed to overwrite this color change. 0 NO CHANGE No color change 1 CHANGE TO RED Color change to red...
  • Page 32: Preselection 3 Menu

    Preselection 3 Menu SOURCE 3 The reference source for preselection 3, see PRESELECTION 1 MENU. MODE 3 Switching conditions for preselection 3, see PRESELECTION 1 MENU (except trailing preselection) see PRESELECTION 1 MENU Trailing preselection 3: RES>=PRES-TRAIL Display value is greater or equal to PRESELECTION 4 – PRESELECTION 3 PRESELECTION 3 is the trailing preselection of PRESELECTION 4.
  • Page 33: Preselection 4 Menu

    Preselection 4 Menu SOURCE 4 The reference source for preselection 4, see PRESELECTION 1 MENU. MODE 4 Switching conditions for preselection 4, see PRESELECTION 1 MENU (except trailing preselection) see PRESELECTION 1 MENU. Trailing preselection 4: RES>=PRES-TRAIL Display value is greater or equal to PRESELECTION 3 – PRESELECTION4 PRESELECTION 4 is the trailing preselection of PRESELECTION 3.
  • Page 34: Serial Menu

    Serial Menu This menu defines the basic settings of serial interface. This function is only available for devices with option CO, CR, AO or AR UNIT NUMBER This parameter defines the serial device address. The addresses between 11 and 99 can be assigned to the device.
  • Page 35 This parameter enables the Modbus protocol and determines the Modbus address. (For details of the Modbus communication please refer to the additional manual Modbus_RTU) Modbus disabled: Serial interface is using Lecom protocol (Motrona default protocol) Modbus enabled: 1 … 247 Serial interface is using Modbus RTU protocol The set value is the Modbus address of the device.
  • Page 36: Analog Menu

    Analog Menu This menu defines the basic settings of the analog output. This function is only available for devices with option AO or AR. ANALOG SOURCE This parameter defines the reference source for analog output. FIELDBUS VALUE 1 Reference source is the process data value 1 FIELDBUS VALUE 2 Reference source is the process data value 2 LINKAGE RESULT...
  • Page 37: Command Menu

    Command Menu INPUT 1 ACTION (function Input 1) This parameter defines the function of the input “Ctrl. In 1”. No function FREEZE Freeze actual display value KEY LOCK Disable touch screen LOCK RELEASE Release latching of all outputs/relays (d) (s) RESET MIN/MAX Reset of the min.
  • Page 38 Continuation “Command Menu“: INPUT 1 CONFIG This parameter defines the switching characteristics of the input “Ctrl. In 1”. ACTIVE LOW Active at „LOW“ (static) ACTIVE HIGH Active at „HIGH“ (static) RISING EDGE Activate at rising edge FALLING EDGE Activate at falling edge INPUT 2 ACTION This parameter defines the function of the input “Ctrl.
  • Page 39: Display Menu

    Display Menu Parameter changes become active only after closing the menu selection. START DISPLAY This parameter defines the start display after switching on device. STANDARD Display of a value with unit and status bar LARGE Large display (only the parameter „LARGE DISPLAY“ is active) DOUBLE Two-line display without units DOUBLE WITH UNIT...
  • Page 40 Continuation “Display Menu“: COLOR This parameter defines the display color. Event-depending change of the display color by a switching condition is possible (see PRESELECTION 1…4 MENU). Event-depending changes are only available for devices with option CO, AO or RL. Red display Green display GREEN YELLOW...
  • Page 41: Appendix

    All codes shown in the parameter SERIAL VALUE are available for serial readout by PC or PLC. The communication of Motrona devices is based on the Drivecom protocol according to ISO 1745 or the Modbus RTU protocol. All protocol details can be found in our manual SERPRO (Drivecom) and Modbus_RTU_oi_e (Modbus RTU) for motrona devives which you can find on our homepage www.motrona.com.
  • Page 42: Parameter/ Indices And Serial Codes

    Parameter/ Indices and Serial Codes Index Serial Menu Name Default (hex) Code GENERAL MENU OPERATIONAL MODE 0001 GENERAL MENU ENCODER SUPPLY 0002 GENERAL MENU PIN PRESELECTION 0003 9999 GENERAL MENU PIN PARAMETER 0004 9999 GENERAL MENU FACTORY SETTINGS 0005 GENERAL MENU –...
  • Page 43 Continuation “Parameter / Indices / Serial Codes“: Index Serial Menu Name Default (hex) Code 35 PRESELECTION 1 MENU SOURCE 1 002D 36 PRESELECTION 1 MENU MODE 1 002E 37 PRESELECTION 1 MENU HYSTERESIS 1 002F 99999 38 PRESELECTION 1 MENU PULSE TIME 1 (S) 0030 60000...
  • Page 44 Continuation “Parameter / Indices / Serial Codes“: Index Serial Menu Name Default (hex) Code SERIAL MENU UNIT NUMBER 0059 SERIAL MENU SERIAL BAUD RATE 005A SERIAL MENU SERIAL FORMAT 005B SERIAL MENU SERIAL PROTOCOL 005C SERIAL MENU SERIAL TIMER (S) 005D 60000 SERIAL MENU...
  • Page 45: Commands

    Commands: Index Serial Command Function (hex) Code 0 FREEZE DISPLAY Freeze actual display value 1000 1 KEY LOCK (TOUCH DISABLE) Disable touch screen 1001 2 LOCK RELEASE Release latching of all outputs/relays 1002 3 CLEAR MIN MAX Reset of the min. / max. values 1003 4 SERIAL PRINT Sending serial data (see SERIAL VALUE)
  • Page 46 Variables (Actual values): Index Serial Actual value Function (hex) Code Scaled_Result_FB_Value_1 Scaled process data value 1 (display value) 4800 Scaled_Result_FB_Value_2 Scaled process data value 2 (display value) 4801 Scaled_Result_Linkage Scaled linked display value 4802 Unscaled_FB_Value_1 Process data value 1 (as received via PROFINET) 4000 Unscaled_FB_Value_2 Process data value 2 (as received via PROFINET)
  • Page 47 Dimensions Pn350_01a_oi_e.docx / Mai-23 Seite 47 / 49...
  • Page 48 Technical Specifications Technical Specification: Connection: Connection type: Screw terminals, 1,5 mm² / AWG 16 Power supply DC: Input voltage: 18 … 30 VDC Protection circuit: Reverse polarity protection Consumption: ca. 100 mA (unloaded) Fuse protection: extern: T 0,5 A Power supply AC: Input voltage: 115 …...
  • Page 49 Continuation “Technical Specifications”: Display: Type: Graphic-LCD with backlight Display range: 8 digits plus sign (-99999999 … 99999999) Digit height (single + 13 mm / 0.51 inch dual): Digit height (large 26 mm / 1,02 inch display Color: red/ green/ yellow (switchable) Operation: touch screen (resistive) Housing:...