Common Faults and Solutions

If your solar air conditioner cannot work normally, please check the following items before maintenance. If the faults
cannot be solved, please contact an HVAC technician or the distributor.
Phenomenon
Out of operation
1. Power failure
2. Breaker tripping
3. Voltage is exceedingly low.
4. Air conditioner fuse is burnt out.
5. Air conditioner is turned off as a
6. Air conditioner is in defrost mode.
Poor cooling and
1.
heating effect
2.
3.
4.
5.
6.
7.
8.
Strange noise
1. Water flow sound
from unit
2. Exhaust sound
3. Arrangement is instable.
4. The operation noise is obviously
Compressor
1. The temperature setting is incorrect.
2. The LCD shows Timer is 'on'.
cannot work.
3. For protection, the compressor will
Fan does not
1. If the heat pump blows when the
immediately blow
when heating.
The compressor
1. The input voltage is exceedingly low.
starts and stops
2. Too many appliances are on the
frequently.
3. The room does not retain heat
If your solar air conditioner is not working normally, please check above items before performing any maintenance or
service. If the faults cannot be solved, please contact an HVAC technician or the distributor.
YMGI, Engineered Comfort Products for A Sustainable and Efficient Green World!
YMGI: Your Modern Green Idea
Possible Reason
result of the timer being set
incorrectly.
The filters are dirty or blocked
A heat source or the number people
are indoors are generating heat
above the unit's capacity.
Temperature setting is incorrect.
The air inlet or air outlet of the Indoor
Unit are blocked.
A window or the door is open.
Outdoor temperature is below 0℃
while heating.
Refrigerant level is low.
The solar panels are not in direct
sunlight.
unusual.
not work in the first 3 minutes. Please
wait for a moment.
evaporator is not preheated, the air
circulated will be cold. Please wait for
the evaporator to preheat.
same line. The voltage for the air
conditioner is insufficient.
Solution
1. Reconnect the power supply
2. Contact a service technician
3. Consult the electrician or distributor. Buy
a stabilizing voltage supply to ensure
operation. (below 42v)
4. Change the fuse or consult a service
technician.
5. Cancel the Timer, shut down, and restart
the system.
6. Please wait for a moment.
1. Clean filters to improve air flow efficiency
2. Remove the heat source if possible.
(Make sure your air conditioner has the
correct capacity when purchasing.)
3. Reset the temperature.
4. Remove objects so airflow is
unrestricted
5. Close doors and windows to avoid
conditioned air escaping.
6. Other subsidiary heating apparatuses
can be applied simultaneously.
7. Contact a technician if refrigerant is low.
8. Move solar panels so they face to sun.
1. Refrigerant is circulating in the machine
when the air conditioner is running or
switches off. Please wait for a moment.
2. The sound of the four way valve
switching. Please wait for a moment.
3. Contact your installation technician. The
system may be installed incorrectly.
4. If unusual noise is heard, please contact
a service technician.
1. Reset the temperature.
2. Cancel the Timer, then restart the
system.
3. This is a normal phenomenon. Please
wait for a moment.
1. Please wait for a moment. Allow the coil
to preheat.
1. Check the power source (voltage and
wire diameter). When the voltage is low,
and the wire gauge may be too small.
You can also buy a power stabilizer, or
wire the system to municipal power. You
may also wish to consult an HVAC
technician or the distributor.
2. Prepare a special power cord for the air
conditioner.
3. Improve the insulation of the room. Also
check for any open windows, doors, or
drafts that may be caused by improper
insulation.