ECONO COOL OPERATION

Use this operation when you want to be comfortable in COOL mode even with energy saved.
Perform the following operations while the unit is operat-
ing in the MANUAL COOL mode.
I
˚C
Press the
CLOCK
AMPM
When the
conditioner performs swing operation in various cycle according to the tem-
AMPM
perature of air conditioner.
TOO
TOO
ON/OFF
Also SET TEMPERATURE is automatically set 2°C higher than in COOL mode.
WARM
COOL
To release the ECONO COOL operation:
I
Press the
FAN
STOP
I FEEL COOL
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
VANE
START
HEAT
DRY
/FAN
• When the
MODE
HR.
the ECONO COOL operation, ECONO COOL operation is released.
ECONO COOL
MIN.
• The
RESET CLOCK
are available.
What is "ECONO COOL"?
Swing air flow (change of air flow) makes you feel cooler than constant air flow. So, even though the set temperature is
automatically set 2°C higher, it is possible to perform cooling operation with keeping comfort. As a result, energy can be saved.

TIMER OPERATION (ON/OFF TIMER)

It is convenient to set the timer when you go to bed, when you get home, when you get up, etc.
1
How to set the ON timer
START
Press the
button during operation.
Each time the button is pressed, the ON timer mode
2
alternates between ON and OFF.
HR.
Set the time of the timer using the
MIN.
buttons.
HR.
Each time the
button is pressed, the set time
MIN.
increases by 1 hour; each time the
button is
pressed, the set time increases by 10 minutes.
To release the ON timer:
I
START
Press the
button.
Programming timer operation
The ON timer and the OFF timer can be used in combination. The timer of the set time that is reached first will operate first.
(" " mark indicates the order of timer operations.)
• If the current time has not been set, the timer operation cannot be used.
NOTE:
If the main power is turned off or a power failure occurs while AUTO START/STOP timer is active, the timer setting is
cancelled. As these models are equipped with an auto restart function, the air conditioner starts operating with timer
cancelled at the same time that power is restored.
8
ECONO COOL
button.
(ECONO COOL) operation is selected in COOL mode, the air
ECONO COOL
button again.
button is pressed or the operation mode is changed during
TOO
TOO
FAN
WARM
COOL
button, the
or
button and ON/OFF timer (explained below)
1
How to set the OFF timer
STOP
Press the
button during operation.
Each time the button is pressed, the OFF timer mode
2
alternates between ON and OFF.
and
Set the time of the timer using the
MIN.
buttons.
HR.
Each time the
button is pressed, the set time
increases by 1 hour; each time the
pressed, the set time increases by 10 minutes.
To release the OFF timer:
I
STOP
Press the
button.
WHEN THE AIR CONDITIONER IS NOT GOING TO BE
USED FOR A LONG TIME
When it is not going to be used for a long
1
time:
Perform the FAN operation for 3 or 4 hours
to dry the inside of the air conditioner.
COOL & HEAT type:
• To perform FAN operation, set the remote control-
ler to the highest temperature in the MANUAL COOL
mode. (Refer to page 7.)
COOL ONLY type:
2
• Select the FAN mode. (Refer to page 7.)
Turn off the breaker and/or disconnect the
power supply plug.
CAUTION:
Turn off the breaker or disconnect the power supply plug
when the air conditioner is not going to be used for a
long time.
3
Dirt may collect and this may cause a fire.
Remove the batteries from the remote con-
troller.
CAUTION:
To prevent liquid leakage, take out all batteries when the
remote controller is not going to be used for a long time.

MAINTENANCE

HR.
Before starting maintenance
and
I
Turn off the breaker and/or disconnect the
power supply plug.
MIN.
button is
CAUTION:
When the unit is to be cleaned, switch it off and discon-
nect the power supply plug or turn off the breaker. Since
the fan rotates at high speed during operation, it may
cause an injury.
When the air conditioner is to be used
1
again:
Clean the air filter and install it in the indoor
unit.
2
(Refer to page 9 for cleaning instructions.)
Check that the air inlet and outlet of the in-
door/outdoor units are not blocked with any
3
obstacles.
Check that the earth is connected correctly.
CAUTION:
Earth the unit.
Do not connect the earth to a gas pipe, water pipe, light-
ning rod or the earth of a telephone. If the earthing is
incorrect, it may cause an electric shock.
Cleaning the indoor unit
I
Clean the unit using a soft dry cloth.
• If the dirt is noticeable, wipe the unit with a cloth
soaked in a solution of mild detergent diluted in luke-
warm water.
• Do not use gasoline, benzine, polishing powder, or
insecticide. The unit may be damaged.