2�5 Proper Operation Of The Generator Set; Loading - Bison BS3500DSE Owner's Manual

Air-cooled diesel engine generator set
Table of Contents

Advertisement

2-5 Proper operation of the generator set
2-5.1 Operating the diesel engine
I. Pre-heat the diesel engine for 3 minutes
under no load conditionv.
2. First check the height of the lubricating
oil level, if it is low, refill it. Our diesel
engines are equipped with an alarm
ystem that will notify you if the oil
pressure is to low. The alarm system
ill shut down the engine if the oil
pressure is to low.
3. Do not adjust the speed limit regulation
nut or the fuel adjustment bolt. These
bolts have been set by the factory
already, changing them will affect th
porperties of the engine performance.
uel adjustment
bolt
2-5.2 Checks during engine operation
I. Check to see if there are abnormal
1101s es.
2. Check to see if the performance i
good or bad.
,.,
`'
High-pressure
fuel pipe nut
10
3. Check the color of the exhaust gase
(whether it is too black or too white).
lf any of these conditions exist, stop
the engine and find the cause of the
problem. If no problems are found,
please contact your local dealer or
our nearest company branch.

2-6 Loading

2-6.1 Load condition
Exert loads in accordance with the speci­
fied parameter.,.
2-6.2 Output of electricity
I. Raise the revolutions per minute
turn the speed handle to the max
etting) of the generator to get the
maximum power out of th
generator. If not, the automatic volt­
age regulator device will excite and
doing this for long periods of time
i II cause the capacitor to bum.
2. For the rated speed of the generator
please refer to Chapter I, item 1-1
technical specification and data.
3. Observe the pointer of the voltmeter
it should point to 220V土5%(50Hz).
(For 60Hz set, it will be 240V士5%).
This is the reading of the voltage at