Climatic sensor

Advertisement

Table 2 - available "Wind" thresholds
2
2 flashes
40 kph
3
3 flashes
60 kph
4
4 flashes
80 kph
5
5 flashes
100 kph
7 - DIAGNOSTICS
You can enable "DIAGNOSTICS mode" at any time to
check whether the weather conditions at the time are
above or below the threshold values and to identify
malfunctions. To enable diagnostics:
1. Press and hold the
Button or
around 3 to 5 seconds, release when the LED starts
flashing orange.
2. Now watch the LED and check the sequence of
flashes against Table 3.
Caution! – Diagnostics mode can only be used for
reading signals off the LED, not for operating the awn-
ing.
Note – To check whether the device is really faulty, run
the testing procedures given in chapter 5.
Note – If more than one weather condition is detected,
the LED will signal them in order: wind > rain > sun.
Table 3 - LED diagnostics signals
6 alternate Red/Green flashes = No thresh-
1
olds have been exceeded
3 Red flashes = The wind threshold has been
2
exceeded
3 Orange flashes = The rain has been de-
3
tected
3 Green flashes = The sun threshold has
4
been exceeded
8 - RESTORING FACTORY DEFAULTS (FIG. F)
The reset procedure will restore default values of
thresholds:
1. Press and hold the
to 11 seconds, release when the LED starts flash-
ing red.
2. The LED:
- turns RED for 10 seconds;
- turns OFF for 10 seconds;
- flashes GREEN 1 time to confirm reset.

9 - BATTERY PROTECTION

Button for
To protect the battery the WSC sensor will enter the
sleep mode, when battery level is too low. The LED
signals low battery level with three short red flashes.
The unit may enter sleep mode if mounted in a location
that does not receive sufficient exposure to light. When
the unit is in sleep mode, it does not control automa-
tion.
10 - OPERATING THE MENU
Time
LED
<1s
green
(click)
blink normal
green
2-4s
blink normal
orange
4-6s
blink normal
>6s
led off
Button and
Button for 9
Action
Sunlight Level
Threshold
(number of blinks
show the set level
threshold)
Sunlight test
Diagnostic proce-
dure
Menu end
Time
LED
Action
<1s
red
Wind Level Thresh-
(click)
blink normal
old
red
2-4s
Wind test
blink normal
orange
Diagnostic proce-
4-6s
blink normal
dure
>6s
led off
Menu end
Memorising MONO
2-4s
red on
(see 4.1)
Memorising BIDI
4-6s
green on
(see 4.3)
Memorising BIDI
6-8s
orange on
(see 4.2)
Memorisation
8-10s
green on
through the
"Enable Code"
20-26s
red
Enter ship mode or
(WSC)
blink normal
software update
red
Enter software
20-26s
blink normal
update
>26s
led off
Menu end
2-4s
orange
Rain test
(WSR)
blink normal
red
9-11s
Device factory reset
blink normal