Overview; General Description; Safety Regulations - ABB JOKAB SAFETY Tina 6A Original Instructions Manual

Adaptor unit
Table of Contents

Advertisement

2

Overview

General description

ABB/Jokab Safety adaptor units are used to adapt conventional safety sensors where the safety relies on e.g. one-
or two-channel static signals, OSSD outputs, or short circuit detection, to the dynamic safety circuit monitored by a
Vital safety module or Pluto safety-PLC.
Tina 6A is used to adapt safety sensors that rely on the detection of short circuits to the dynamic safety circuit.
Examples of such safety sensors are safety mats with relay outputs and safety sensors using safety contact rails.
Tina 6A is equipped with a male 5-pole M12-connector for quick installation to the dynamic safety circuit and a
female 5-pole M12-connector for easy connection to the safety sensor. The unit is also equipped with a LED for
visual status information of the safety sensor and the dynamic safety circuit.
The Tina 6A adaptor unit is intended for use in safety circuits in accordance with EN 60204-1.

Safety regulations

Warning!
Carefully read through this entire manual before using the device.
The devices shall be installed by a trained electrician following the Safety regulations, standards and the Machine
directive.
Failure to comply with instructions, operation that is not in accordance with the use prescribed in these instructions,
improper installation or handling of the device can affect the safety of people and the plant.
For installation and prescribed use of the product, the special notes in the instructions must be carefully observed
and the technical standards relevant to the application must be considered.
In case of failure to comply with the instructions or standards, especially when tampering with and/or modifying the
product, any liability is excluded.
2TLC172133M0201, rev. A
5
www.jokabsafety.com
2011-09-22

Advertisement

Table of Contents
loading

Table of Contents