Typical Mig Process Control Settings - Hobart Handler 130 XL Owner's Manual

Table of Contents

Advertisement

7-2. Typical MIG Process Control Settings

NOTE
Material thickness determines weld
parameters.
Wire
Size
.023 in
.030 in
.035 in
Voltage controls height and width of weld bead.
Wire speed (amperage) controls weld pe-
netration (wire speed = burn-off rate)
OM-210 082 Page 22
These settings are guidelines only. Material and wire type, joint design, fitup,
position, shielding gas, etc. affect settings. Test welds to be sure they comply to
specifications.
Wire Size
.035 in
.023 in
.030 in
.035 in
Recommendation
3.5 in per ampere
3.5 x 125 A = 437 ipm
2 in per ampere
2 x 125 A = 250 ipm
1.6 in per ampere
1.6 x 125 A = 200 ipm
Low voltage: wire stubs into work
High voltage: arc is unstable (spatter)
Set voltage midway between high/low voltage.
1/8 or
.125 in
Amperage Range
30 – 90 A
40 – 145 A
50 – 180 A
Wire Speed
(Approx.)
Convert Material
Thickness to
Amperage (A)
(.001 in = 1 ampere)
.125 in = 125 A
Select Wire Size
Select Wire Speed
(Amperage)
125 A based on 1/8 in
material thickness
ipm = inch per minute
Select Voltage
Ref. ST-802 026