Feature/Service: Automatic Electronic Diagnostics
The timer computer has a self-diagnostic function for the electrical system (except input power
and water meter). The computer monitors the electronic components and circuits for correct
operation. If a malfunction occurs, an error code appears in the timer display.
The chart on Error Codes shows the error codes that could appear and possible defects for each
code. While an error code is displayed, the TOUCH or HOLD and DATA buttons remain operable
so you can perform the Manually Initiated Electronic Diagnostics.
ERROR CODE DISPLAYED ERR 01
➨ motor inoperative ➨ wiring harness, or connection to switch ➨ timer (PWA)
POSSIBLE DEFECT
➨ position switch ➨ valve defect causing high torque
To remove an error code: (1) Unplug transformer.
(2) Correct defect.
(3) Plug transformer in.
(4) Wait for at least 6 minutes. The error code will return if the reason
Feature: Other Data Displays
By continuing to press the DATA button, you can scan through four displays of operational
information. This data appears in the bottom portion of the display area.
REMAINING CAPACITY —
remaining. Immediately after a regeneration, 100% shows. As water is used, the percentage
decreases until the next regeneration. During regenerations, the percentage increases.
NOTE: Zero (%) shows until after the first regeneration begins, after connecting to
electrical power.
WATER MANAGEMENT SYSTEM
FLOW RATE, GPM—
FLOW RATE
through the softener (in gallons per minute). Zero shows if water is not passing through the
softener.
WATER MANAGEMENT SYSTEM
GALLONS TODAY—
GALLONS TODAY
count of the total gallons of water that have passed through the softener.
WATER MANAGEMENT SYSTEM
AVG. DAILY GALLONS—
AVG DAILY GALLONS
the household each day over the past seven day period.
NOTE: If preferred, you can set the timer to show the reading in liters instead of gallons.
If GALLONS TODAY or AVG. DAILY GALLONS exceeds 1999, a (x10) indicator appears, this means
you must multiply the number shown by ten.
ERR 02
for the error code was not corrected.
WATER MANAGEMENT SYSTEM
%
This is the percentage of water softening capacity
CAPACITY
GPM
When using soft water, this display shows the flow rate passing
Each day, beginning at midnight, the timer keeps a running
The figure displayed is the average gallons of water used by
ERR 03