Jumper Setup - ASROCK D1541D4U Series User Manual

Server/workstation motherboard
Table of Contents

Advertisement

2.5 Jumper Setup

The illustration shows how jumpers are setup. When the jumper cap is placed on
the pins, the jumper is "Short". If no jumper cap is placed on the pins, the jumper
is "Open". The illustration shows a 3-pin jumper whose pin1 and pin2 are "Short"
when a jumper cap is placed on these 2 pins.
ME Recovery Jumper
(3-pin ME_RECOVERY1)
(See p.6, 7, 10 or 13)
CPU PECI Mode Jumper
(3-pin PECI1)
(See p.6, 7, 10 or 13)
NCSI Mode Jumper
(3-pin NCSI_SEL1)
(See p.6, 7, 10 or 13)
PMBUS Mode Jumper
(3-pin PMBUS_ALT_SEL)
(3-pin PMBUS_CLK_
SEL)
(3-pin PMBUS_SATA_
SEL)
(See p.6, 7, 10 or 13)
28
Normal Mode (Default)
CPU PECI connected to PCH CPU PECI connected to
NCSI is set to onboard LAN1
(Default)
PMBus connected to BMC
(Default)
ME Recovery Mode
BMC (Default)
NCSI is set to Mezzanine
Card
PMBus connected to PCH