Oil Capacities (ounces) - Standard Units
Mounting
Position
1 - Worm Over
2 - Worm Under
* Shipped Dry
4.
LUBRICATION - The precision - made gears and bearings in our reducers require high-grade lubricants of
the proper viscosity to maintain trouble- free performance. All standard reducers ordered from the factory
are filled with ISO viscosity grade Mobil Glygoyle 460 polyalkalene glycol (PAG) lubricant. If oil needs to
be added or changed, ONLY compatible polyglycol lubricants should be used. Contact the factory for
more information.
5.
TEMPERATURE - Most Titan Units are supplied with wormgear reducers. These units may run at
temperatures between 100 degrees to 200 degrees F. (Higher temperatures are especially common during
start up). There is NO NEED TO WORRY unless temperatures exceed 200 degrees F.
6.
GENERAL MAINTENANCE - Regular inspection to insure the reducer bolts and screws are tight, correct
alignment of shaft and/or coupling, no major oil leaks, no excessive heating and no unusual vibration or
noise will insure maximum life and performance of the reducer.
BEARINGS
1. LUBRICATION - Bearings used on Titan Conveyors are normally pre-lubed for life. If customer requested,
re-lube bearings are provided, the use of a #2 consistency lithium based grease is advised.
Standard Gear Reducer Mounting Positions
& Vent Plug, Level and Drain Locations
813 815 818 821 824 826 830 832
4
12
12
20
24
8
16
20
28
40
16 0z. = 1 pint
2 pints = 1 quart
4 quarts = 1 gallon
1 gallon = 128 oz. = 231 Cu. in.
UNIT SIZE
842
852 860
40
56
72
112
188 312
60
84
108
152
304 328
FIGURE 10
12
870*
880*
8100*
35
48
72
32-3/4
51-1/4
80
5/12