Instruction Manual Diaphragm Valve DV-5625-U / SS 1. Introduction The DV-5625-U /SS is a diaphragm valve designed for precise flow control of low to medium viscosity materials (under 10,000 cps). The valve is ideal for dispensing cyanoacrylates, reagents, electrolytes, glues, solvents, paints, alcohol and other volatile substances. Shot sizes may be fine tuned by turning the stroke adjustment knob at the top of the valve.
VIEWEG Instruction Manual Diaphragm Valve DV-5625-U / SS 3. Part Description Stroke index Tape: Stroke Adjust Knob: The range of stroke for flux control You con control the flux. If you lock is 0 ... 0,6 mm. This range is con- the knob the stroke will be shorter.
VIEWEG Instruction Manual Diaphragm Valve DV-5625-U / SS 5. Operating Procedure 5-1. Setup example for general installation: AIR IN FROM COMPRESSOR VALVE CONTROLLER VC-1000 MATERIAL IN CARTRIDGE OPERATING AIR LINE MATERIAL IN MATERIAL RESERVOIR DIAPHRAGM VALVE IN BOTTLE DV-5625-U /-SS...
Page 7
VIEWEG Instruction Manual Diaphragm Valve DV-5625-U / SS 5-1-1) Fasten the valve firmly using mount hole. (M5*P0.8*D98) 5-1-2) Connect air hose to Air In Port and Controller. Valve driving pressure is Min 4.0 bar or more. 5-1-3) Connect fitting for material supply hose to the inner port (BSPT1/8”) Notice 5-1-4) Do not insert fitting too deeply (7 mm or more).
Page 8
VIEWEG Instruction Manual Diaphragm Valve DV-5625-U / SS 5-1-7) After steady mode in controller and reducing pressure of pressure container, make dispensing the liquid come out slowly. (This is to remove bubble and dispense the first liquid from valve) 5-1-8) Choose “Prog” or “Manual” mode of controller according to the state of dispens- ing.
VIEWEG Instruction Manual Diaphragm Valve DV-5625-U / SS 5-2. Maintenance 5-2-1) Washing copy 2 copy 3 Wash valve thoroughly after using if dispensed liquid has tendency to be stiff or has possibility to damage liquid contacting part. First of all dispense all liquid entirely from pressure container, liquid supply hose and liquid contacting part until sufficient air comes out.
Page 10
VIEWEG Instruction Manual Diaphragm Valve DV-5625-U / SS Notice If it isn‘t fit thread properly leakage may occur. After fixing diaphragm at regular intervals(0.4mm) like the picture, for matching cylinder body and mount screw, please turn to the location that you want using a screw driver like next picture.