Stanley SXAC2036121 Manual page 11

Air compressor 2hp 36l
Table of Contents

Advertisement

HANDLE
1. Loosen bolts in tubes welded to the tank.
2. Push handle into tubes welded on the tank.
3. Tighten the bolts to hold handle in place, Pic. 3.
AIR FILTER
The supplied air filter must be used.
Failure to do so may result in irreparable damage and
will void the warranty, Pic. 4.
To install;
1. Carefully screw supplied air filter into the threaded
hole on the top of the pump head. This only needs
to be done up by hand. Do not use tools to tighten
air filter.
NOTE: Do not OVER TIGHTEN as this may damage the
air filter or cylinder head which will NOT be covered
under warranty.
STARTING AND STOPPING YOUR AIR
COMPRESSOR
Pic. 5
NOTE: Always ensure that you plug your air compressor
into a standard 240V AC power point. Never use an
extension cord as this can lead to a voltage drop which
may cause power loss and over heating. Use a longer air
hose if you need to get closer to your work area.
Always start and stop the compressor using the ON/OFF
switch on the Pressure Switch (Pic. 1 Item 9 and 10 as well
as Pic. 5). Damage caused by not using this switch will not
be covered by warranty.
To turn your air compressor ON;
Lift up the red ON / OFF switch on top of the
pressure switch.
To turn your air compressor OFF;
Push down the red ON / OFF switch on top of the
pressure switch.
PIC. 3
PIC. 4
PIC. 5
Lift switch
up for on
11
Tighten bolts to hold handle
Slide handle
into tubes
Push switch
down for off

Advertisement

Table of Contents
loading

Table of Contents