Advertisement

Quick Links

USER MANUAL
Protect alpha.
Protect alpha. 1200
EN
Uninterruptible Power Supply

Advertisement

Table of Contents
loading

Summary of Contents for AEG Protect alpha. 1200

  • Page 1 USER MANUAL Protect alpha. Protect alpha. 1200 Uninterruptible Power Supply...
  • Page 2: Table Of Contents

    CONTENTS 1. Safety – caution ................. 3 2. Introduction ..................5 3. Trouble shooting ................6 4. System description ................7 4.1. Inspection ......................7 4.2. Charging ......................8 4.3. Placement ......................8 4.4. Connection .......................9 4.5. Turn On/Off ......................9 4.6. DC-start ......................9 4.7.
  • Page 3: Safety - Caution

    1. SAFETY – CAUTION • This UPS utilizes voltages that may be hazardous. Do not attempt to disassemble the unit. The unit contains no user serviceable parts. Only qualified service personnel may perform repairs. • Internal battery voltage is 24 V DC. Sealed, lead-acid, 6 cell battery – two pcs. • Connection to any other type of socket other than a two-pole, three-wire grounded socket may result in shock hazard as well as violating local electrical codes.
  • Page 4 • Servicing of batteries should be performed or supervised by personnel trained in batteries and the required precautions. Keep unauthorized personnel away from batteries. • When replacing batteries, replace with the same number and type of sealed lead-acid batteries. The maximum ambient temperature rating is 40 °C. • This pluggable type A equipment, with battery already installed by the supplier, is operator installable and may be operated by non-technical users.
  • Page 5: Introduction

    2. INTRODUCTION This UPS is specially designed for Personal Computer use and has multiple functions. Its light weight, compact design fits perfectly to the limited working environment. This line of UPS is equipped with boost and buck AVR to stabilize input voltage range.
  • Page 6: Trouble Shooting

    3. TROUBLE SHOOTING Symptom Possible Cause Remedy No LED display 1. Battery weak 1. Charge battery for on the front up to 8 hours panel 2. Battery defective 2. Replace with the same type of battery 3. Power switch is 3.
  • Page 7: System Description

    4. SYSTEM DESCRIPTION Front panel 1. Power switch LED indicators: 2. Normal: Green 3. Battery mode: Yellow flashing 4. AC mode: Green 5. Fault mode: Back panel 1. AC input 2. Output sockets 3. USB & RJ45 communication 4.1. INSPECTION Remove the UPS from its packaging and inspect it for damage that may have occurred during shipping.
  • Page 8: Charging

    4.2. CHARGING This unit is shipped from the factory with its internal battery fully charged, however, some charge may be lost during shipping and the battery should be recharged prior to use. Turn on the UPS, plug the unit into an appropriate power supply and allow the UPS to charge fully by leaving it plugged in for at least 6 hours with no load connected (i.e.
  • Page 9: Connection

    4.4. CONNECTION Plug the UPS into a 2-pole, 3-wire grounded socket. Then connect one computer-related device into each of the power sockets supplied on the back of the UPS. 4.5. TURN ON/OFF To turn on the UPS unit, press the power switch lightly. To turn off the UPS unit, press the power switch again.
  • Page 10: Specification

    5. SPECIFICATION MODEL Protect alpha. 1200 VA / W 1200 VA / 600 W CAPACITY INPUT Voltage 120 V AC or 230 V AC Voltage range 85 – 145 V AC or 170 – 280 V AC Voltage OUTPUT 120 V AC or...
  • Page 11: Ce Conformity

    6. CE CONFORMITY...
  • Page 12 MODEL: SERIAL NUMBER: PURCHASE DATE: DEALER STAMP/SIGNATURE Emil-Siepmann-Str. 32 59581 Warstein-Belecke – Germany Tel.: +49 180 523 4787 – Fax: +49 180 523 4789 www.aegps.com...

Table of Contents