Dual inlet dual flow manifold system
Table of Contents

Advertisement

Table of Contents

Safety Information ...........................................................................1
Inlet and Outlet Connections ............................................................3
Product Dimensions ........................................................................3
How to Use "Push-in" Fittings (Collet) .............................................4
Dual Inlet Dual Flow (DIDF) Manifold System and Cartridges
The DIDF260-CL Dual Inlet Dual Flow (DIDF) System helps to provide consistent high quality water for multiple applications. The inlet water for the
ice machine enters the manifold on the left rear side, and the inlet water for cold beverage enters the manifold on the right rear side. Each water
stream (ice, beverage) has a separate outlet connection fitting.
The left single cartridge (yellow label) is model HF60-S-SR5. It is critical that this cartridge be installed in the left most manifold head which
also has a yellow 3M label. The cartridge is keyed such that it will not fit properly if installed in either of the other manifold heads. The media in
this cartridge is a pleated nylon membrane with a time released scale inhibitor. It filters the water going to the ice machine. The water for the ice
machine exits the manifold on the left side front connection (labeled "Outlet Ice").
The two cartridges to the right of the ice cartridge (blue label) are model HF60-CL. These cartridges are plumbed in parallel and filter the water
going to post mix the beverage. The HF60-CL cartridges will not fit into the left most (ice) head. The water for cold beverage exits the manifold on
the right front connection (labeled "Outlet Beverage").

Inlet and Outlet Connections

The water inlets are on the rear left and right sides, and the water outlets are on the front left and right sides. All inlets and outlets are identified
with their corresponding labels. The water inlets fitting size is ¾" NPT male and the ice and beverage outlet fitting size is ¾" NPT male. Built-in
check valves (non-return) are incorporated into both outlets.

Product Dimensions

3" (7.6 cm) MINIMUM DISTANCE REQUIRED TO REMOVE CARTRIDGE
Equipment Installation .....................................................................5
Cartridge Change-out Procedure .....................................................6
Troubleshooting ...............................................................................7
Replacement Parts Listing ...............................................................8
Limited Warranty .............................................................................9
Figure 1
3
TOP VIEW

Advertisement

Table of Contents
loading

Table of Contents